beautypg.com

Dehumidification mode, E-21 – Sharp CV-P09LX User Manual

Page 23

background image

ENGLISH

DEHUMIDIFICATION MODE

1

Remove the exhaust hose (See Page 17)

2

Turn the drainage nozzle to the OPEN position.

3

Pull the stopcock out from the drainage nozzle.

• When the stopcock is removed, a small amount of water

may be discharged from the drainage nozzle.

• Always perform this procedure with the unit turned off.

Drain water will spout out if attempted during operation.

4

I

nsert the hose clamp onto a standard commer-

cially-available hose (5/8" inner diameter, 7/8" outer
diameter) and attach the drain grommet to the

hose.

5

Attach the hose to the drainage nozzle, and secure
it with the hose clamp.

• Insert the hose securely into a container with a minimum

capacity of 3

1

/

2

gallons. Be sure to monitor the water level

in the container and empty as necessary. Do not operate in
dehumidify mode for more than 8 hours at a time. Be sure
to empty the water container whenever dehumidify mode is
started. Failure to empty the water container can cause the
container to overflow and cause damage to underlying
materials.

• Set the hose sloping downwards for easier drainage.

Moreover, do not bend the hose at any point, nor allow
the end to be submerged in water.

Dehumidification with no container

E-21

2

1

In this mode, the air conditioner dehumidifies the room.

CAUTION

When operating dehumidification with container, the unit generates heat during dehumidifica-

tion mode and the room temperature will rise. Operate dehumidification with no container if
you don't want the room temperature to rise. This will help to slightly drop the room

temperature, but dehumidification performance will become less effective than when operat-

ing dehumidification with container.

1

Press the MODE button to select DEHU-
MIDIFICATION mode.

COOL

DEHUM

FAN

VENT

2

Press the power button to start opera-

tion.

• The red OPERATION lamp on the unit will light.

• The temperature cannot be set.

• The fan speed is preset to AUTO and cannot be

changed.

TO TURN OFF

Press the POWER button again.

• The red OPERATION lamp on the unit will turn off.

Dehumidification with container

Drainage nozzle

Stopcock

Drain grommet

Hose clamp

Hose

I

f draining of the water is not desirable, install the exhaust hose (See Page 16), turn the drainage nozzle to the

CLOSE position, and check that the drainage nozzle is covered with the stopcock. In this operation, the water
tank inside the unit may be full, the unit stops operating and then the TIMER, OPERATION and MEGA COOL
lamps are blinking, depending on room condition. In this case, drain out the water within the unit (See Page 29).

"OPEN" position

This manual is related to the following products: