Push buttons, Turning knobs, The inverter – Studer Innotec XPC 1112 User Manual
Page 13: Charge detection system „standby, Overload, Overheating (over temp), Ush buttons, Urning, Nobs, Nverter

STUDER INNOTEC
XP-COMPACT
 
13 
OFF
XP-COMPACT is turned off. Turn-
ing it back on is only possible 
manually. 
XP-COMPACT is for the time be-
ing turned off. Turning it back on 
will follow automatically! 
14
Battery Charger and/or Solar 
Charge Controller are doing an 
equalization cycle 
15-18*
Charge condition of Battery
LED 15 – Absorption time is run-
ning 
25* CURRENT
MONITOR
 Display the value of the output power in % of Pnom (in Inverter Mode) 
and the charge current in Amps. (in Charger Mode) 
4.4 Push
buttons
19
ON/OFF
Turning the XP-COMPACT on and off (Help Button for Programming)
20*
RESET
Alarm Signal off (Help Button for Programming)
21*
Aux. Contact
Control Aux. contact (Help Button for Programming)
4.5 Turning
Knobs
22
CHARGER
Adjustment for max. Charging Current (Not for Solar charge controller)
23
TRANSFER
Adjustment for Transfer Voltage Threshold (TRANSFER – INVERTER)
24
STANDBY
Adjustment for „Standby“ system
* Only on the remote control RCC-01
4.6 The
Inverter
An Inverter is built in the XP-COMPACT, which generates a sinusoidal alternating voltage of a very 
high quality. With this Inverter any alternating voltage consuming appliance 230Vac up to the 
nominal power of your XP-COMPACT can be operated. Thanks to the generous dimensioning of 
the XP-COMPACT, you can operate appliances requiring higher power than the nominal power of 
the XP-COMPACT for a short time. The XP-COMPACT provides up to 3-times the nominal power 
to start motors. 
4.6.1 Charge detection system „Standby“ 
In order to avoid unnecessary discharge of the battery, the inverter switches OFF automatically if 
no consuming appliance is connected and switches ON automatically again if a consuming appli-
ance is connected. The LED 8 blinks if the inverter is in Standby-Mode. The switching-on/starting 
level can be adjusted with the turning knob 24 „STANDBY. Adjusting the switching-on level is as 
follows: Switch off all consuming appliances; turn the Turning Knob 24 to the right until the LED 8 
is blinking, switch on the smallest consuming appliance (i.e. Mobile phone charger); turn the Turn-
ing Knob slowly to the left until LED 8 is lit. 
If the Standby mode is not wanted, turn the Turning Knob 24 to the left, to the OFF position. 
4.6.2 Overload 
If the Inverter is too long or too heavily overloaded, it switches off and LED 13 „OFF“ blinks. After 
approx. 10 seconds the inverter switches on automatically. If the Inverter is overloaded four times 
one after the other in a short time, then it no longer switches on automatically. The LED 13 remains 
lit. Press the push button 19 „ON/OFF“ in order to switch on the inverter. 
4.6.3 Overheating (Over Temp) 
If the Inverter has been overloaded for a long time or it has been working in a too high surrounding 
temperatures, it will switch off. The LED 13 „OFF“ blinks. After cooling down, the inverter switches 
back on automatically. One minute before the inverter switches off for too high temperature it gives 
out an acoustic alarm signal. The Auxiliary Contact programmed in factory to detect the high tem-