Burn hazard, Lighting instructions, Do not touch vent. doing so can result in burns – State GS6 30 YOCT User Manual
Page 21: Warning
21
MATCH
RELIEF
OPENING
DRAFT HOOD
FIGURE 17.
If the flame flutters or is blown out, combustion products are
escaping from the relief opening. If this occurs, do not operate
the water heater until proper adjustments or repairs are made
to the vent pipe system and/or air supply requirements.
FOR YOUR SAFETY READ BEFORE LIGHTING
TO TURN OFF GAS TO APPLIANCE
A. This appliance has a pilot which is lighted by a
piezoelectric igniter. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
v
Do not try to light any appliance.
v
Do not touch any electrical switch; do not use any
phone in your building.
v
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
v
If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
move by hand, don’t try to repair it, call a qualified service
technician. Force or attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance. Water heaters subjected to flood
conditions or anytime the gas controls, main burner or
pilot have been submerged in water require replacement
of the entire water heater.
E. DO NOT USE THIS APPLIANCE IF THERE HAS BEEN AN
IGNITION OF VAPORS. Immediately call a qualified service
technician to inspect the appliance. Water heaters
subjected to a flammable vapors ignition will show a
discoloration on the air intake grid and require
replacement of the entire water heater.
2. Turn the gas control knob clockwise to the “OFF”
position.
1. Turn the temperature dial counterclockwise to its
lowest setting.
WARNING:
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
LIGHTING INSTRUCTIONS
7. Depress the reset button all the way
in and IMMEDIATELY depress the
igniter button until you hear a loud
click. Observe the pilot through the
view port. Do not release the reset
button. Repeat immediately if pilot
does not light on the first try. If the
pilot does not light by the fourth
attempt with the igniter, repeat steps
4 - 7. Continue to hold the button for
about (1) minute after the pilot is lit.
Release the reset button and it will pop
back up. Pilot should remain lit. If the
pilot light goes out, repeat steps 3 - 7.
1. STOP! It is imperative that you read all the safety warnings
before lighting the pilot.
2. Remove the outer door.
3. Turn the temperature dial counterclockwise to its
lowest setting.
4. Depress the dial stop and turn
gas control knob clockwise
to the “OFF” position.
5. To clear any gas that may have
accumulated wait ten (10) minutes.
If you then smell gas, STOP! Follow “B” in the safety
warning above. If you do not smell gas go to the next
step.
6. Turn the gas control knob
counterclockwise
to “PILOT”.
IMPORTANT: If the pilot will not stay lit after several tries,
depress the dial stop and turn gas control knob to “OFF”,
then call your service technician or gas supplier.
IMPORTANT: If the reset button (see graphic at step 3) does
not pop up when released, stop and immediately shut off
the gas at the line valve or tank. Call your service technician
or gas supplier.
8. Turn the gas control knob
counterclockwise
to “ON”.
9. Set the temperature dial to
the desired setting.
10. Replace the outer door.
UNITROL
BEFORE
LIGHTING
READ
ALL
INSTRUCTIONS
CAU
TIO
N
H
O
T
W
A
R
M
V
A
C
A
T
IO
N
CA
UTION
W
AT
ER
INCREA
SE
S
HOTTER
T
H
E
RIS
K OF SCALD
IN
JU
R
Y
V
A
C
AT
IO
N
WA
RM
H
O
T
120° F
BAR
130° F
BAR
INDEX
BARS
GAS
CONTROL
KNOB
WA
RN
IN
G
DIAL
STOP
130° F
BAR
RESET
BUTT ON
RESULT
WILL
DAMAGE
ON DIAL
DO NOT PRY
CAUTION
ON
OFF
P
IL
O
T
RESULT
WILL
DAMAGE
ON DIAL
DO NOT PRY
CAUTION
O N
OF
F
P
IL
O
T
RESULT
WILL
DAMAGE
ON DIAL
DO NOT PRY
CAUTION
O
N
O
F
F
P IL OT
IGNITER
PUSHBUTTON
Robertshaw Gas Control Valve/Thermostat - Lighting Instructions
Checking the Draft
WARNING
Burn Hazard
Do not touch vent.
Doing so can result in burns.
After successfully lighting the water heater, allow the unit to
operate for 15 minutes and check the draft hood relief
opening for proper draft (Figure 17). Make sure all other
appliances in the area are operating and all doors are closed
when performing the draft test. Pass a match flame around
the relief opening of the draft hood. A steady flame drawn
into the opening indicates proper draft.