beautypg.com

Source Technologies ST9530 User Manual

Page 25

background image

Secure MICR Printer User’s Guide

© Source Technologies

September 2005

21

All Rights Reserved

Print MICR CMC7 Font

&%SM7ddd...ddd$

&%SM7

Lead in sequence

ddd...ddd

Data to be printed in CMC7 font

$ Command

terminator


Prints the specified data in the CMC7 MICR font which is used in Europe and South
America. The font and its correct spacing begins at the current cursor position modified by
the MICRpoint adjustment setting at the start of the command. After the terminator is sent,
the printer will return to its default font, and the MICR count will be decremented by one.
Upon receiving this command the printer will check to ensure a MICR toner cartridge is
installed and set the copies parameter to 1. See Appendix B for CMC7 character mapping.

Print Secure Numeric Font &%SMFddd..ddd~

&%SMF

Lead in sequence

ddd...ddd

Data to be printed in this font

~ Command

terminator


The dollar sign ($) is not a command terminator for this command. For both security fonts
the tilde ~ (hex 7E) is the command terminator since the dollar sign is a valid character.

Print ICR Secure Numeric Font &%SMIxxxxxx~

&%SMI

Lead in sequence

xxxxxxxx

Data variables to be printed in this font

~ Command

terminator

Print MicroPrint Line

&%SMMxxxxxxxxx!$

&%SMM

Lead in sequence

xxxxxx

Data to be printed in this font

!

MP designator (optional)

$ Command

terminator


If the exclamation point (!) is used, the “MP” designate will print just above and to the right
of the last character. This is optional and is typically used to notify the check recipient of
the presence of MicroPrinting. Only 0-9, A-Z (upper and lower case) print. Special
characters and spaces disappear.