4. Continue to check temperature, at 5-minute intervals, until two successive readings are within 5°F (3°C) of each

other.

The control should be recalibrated if your reading is not within 20°F (11°C) of the dial setting (350°F or 175°C). If
calibration is required, the additional steps to be taken are these:

5. Hold dial firmly, insert screwdriver through center of dial, and push calibration stem inward. DO NOT TURN THIS

STEM.

6. While holding calibration stem in firmly with screwdriver, turn dial until it is set at the actual oven temperature as

shown by your test instrument. Release pressure on calibration stem. Replace dial insert.

7. Set dial at 400°F (205°C) mark. Check temperature again, as instructed in steps 3 and 4. If the temperature is

not within 20°F (11°C) of the dial setting (400°F or 205°C), it means that the sensing element is inoperative and
the control should be replaced.

Figure 12

Thermostat Calibration and Bypass Flame Adjustment

Bypass Adjuster

Calibration Stem

Dial Insert

Bezel

Dial

C

ONVERSION FROM

O

NE

T

YPE OF

G

AS TO

A

NOTHER

Each range is shipped adjusted and equipped for a specific type of gas (either natural gas or propane). To convert a
range from one type of gas to another, do the following:

1. Refer to service procedures to access all burner orifices.

2. Refer to instructions included with conversion kit.

3. Follow all steps as indicated in the conversion kit.

4. Check for leaks and proper manifold pressure (the procedure is on page 26).

5. Re-light all pilots and check for proper operation.

Note: A kit for conversion to a different type of gas may be purchased from Southbend.