beautypg.com

2 burner and nozzle data tables, Instructions for the installer – Smeg T18G8X2UG User Manual

Page 24

background image

52

Instructions for the Installer

10.2 Burner and Nozzle Data Tables

Burner

R

ATED

HEAT

CAPACITY

(

K

W)

LPG GAS – G30/G31 28/37 mbar

Nozzle

diameter

1/100 mm

By-pass

mm

1/100

Reduced

heat

capacity

(W)

Net

g/h G30

Net

g/h G31

Auxiliary (1)

1.05

50

30

350

763

750

Semi-rapid (2)

1.75

65

33

450

127

125

Rapid (3)

2.3

75

45

800

167

164

Ultra-rapid (4)

3.5

94

65

1500

254

250

Ultra-rapid (5)

3.9

100

65

1500

284

279

Fish (6)

1.9

65

40

900

138

136

Burner

R

ATED

HEAT

CAPACITY

(

K

W)

NATURAL GAS – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced heat capacity

(W)

Auxiliary (1)

1.05

72

350

Semi-rapid (2)

1.75

97

450

Rapid (3)

2.5

108

800

Ultra-rapid (4)

3.5

133

1500

Ultra-rapid (5)

3.9

135

1500

Fish (6)

1.9

94

900

To identify the burners on your hob, refer to the drawings in point "4.
GETTING TO KNOW YOUR APPLIANCE".