Connect the camera to DC 12 V or AC 24 V.
Connecting the Power Cord
For a system with multiple VN-C11s
In a system where more than one VN-C11 are used, turn on the power for a VN-C11 first and
proceed the setting to Other Settings with V.Networks Setup Tool. Only then turn on the power for a
second one and go on to Other Settings with V.Networks Setup Tool. Repeat the procedure for the
other cameras. Refer to the PDF instruction manual inside the supplied CD-ROM.
WARNING
Connect with the appropriate power-supply voltage.The rated voltage for VN-C11 is DC 12 V
or AC 24 V, 50 Hz/60 Hz. If a voltage exceeding the rating is supplied, malfunction, or in the
worst case, fuming or fire, may be caused.
For AC 24 V, ensure that the primary side is insulated with the secondary one.
Note
The IP address of VN-C11 is set to “198.168.0.2” at the factory. Proper access cannot be
established due to IP address redundancy if the power is turned on for multiple cameras at
one time under a single LAN environment. Do not turn on the power for multiple cameras
at the same time. If an IP address redundancy occurred, ensure that only one VN-C11 exists
on a single LAN environment and wait for some time (at least 10 minutes). Or turn off the
power once for all network equipment and turn it on again for proper access to VN-C11.
The power indicator is lit when the power is turned
on.
Power Cord
• Do not connect the power cord to DC 12 V and
AC 24 V at the same time.
• Use a lug plate to securely connect the power
cord to the power ter minals and avoid
misconnection or loose connection.
• For DC 12 V connection, ensure that the
polarities, positive and negative, are correctly
oriented.
• For DC 12 V connection, the ripple voltage
should not exceed 50 mV.
Length: 30 m maximum
UL1007, UL1015 or equivalent
AWG #20 or equivalent, or higher