beautypg.com

0 control functions, Page 17 – Jacuzzi J-280 User Manual

Page 21

background image

page 17

8.0 Control Functions

8.1 Control Panel
A. LED Display: Can

display current water
temperature (default
display), water tem-
perature set point,
selected filtration/
heating mode, and
error messages.

B. Heat Indicator: Lit when heater is on.

C. Jets 1 Button: Turns jets pump #1 on and off. Press once for low

speed; press a second time for high speed; press a third time to
turn pump off.

D. Jets 2 Button: Turns high-speed jets pump #2 on and off. Press

once to turn pump #2 on; press a second time to turn pump #2 off.

E. Light Button Options:

With standard incandescent light: Turns underwater light on and off.

With optional LED lighting system: Turns underwater light and top
rim accent lights on in one of three random modes or one of seven
solid colors. Refer to section 9.4 (page 20) for details.

F. Warmer (+) Button: Increases water temperature set point.

G. Cooler (-) Button: Decreases water temperature set point.

Operation Details

Temperature Adjustment: 65 to 104°F (18 to 40°C). Factory default
setting is 100°F (38°C).

Standard light system: Incandescent light runs for 1 hour, then

automatically shut off for increased bulb life.

Optional LED light system: All LED lights run for 1 hour, then auto-
matically shuts off.

Jets 1/Jets 2 Button Operation: Jets run for 20 minutes when acti-
vated, then turn off automatically to conserve energy. Simply press
either jets button to continue operation for an additional 20 minutes.

1

2

C

A

B

D

E

G

F

1

2

C

A

B

D

E

G

F

This manual is related to the following products: