beautypg.com

0 power requirements – Jacuzzi J-280 User Manual

Page 13

background image

page 9

is not covered under the spas warranty. Please consult your local
state or city building ordinances.

WARNINg: In addition to maintenance of filters and water
chemistry, proper ventilation is recommended to reduce
the risk of exposure to viruses and bacteria that could be
present in the air or water. Consult a licensed architect
or building contractor to determine your specific needs if
installing your spa indoors.

5.0 Power Requirements

Jacuzzi® spas are designed to provide optimum performance and flex-
ibility of use when connected to the maximum electrical service listed
below. Minor circuit board modifications can be performed to allow your
new spa to accept an electrical service other than the factory 50 Amp
operation setting. Note: Refer to pages 35-36 for circuit board configura-
tion details or contact your authorized Jacuzzi dealer.

All J-270/J-280 Models (60Hz)

240V/40A*

240V/50A**

240V/60A***

Voltage:

240 VAC

240 VAC

240 VAC

# of Wires:

3

3

3

Frequency:

60Hz

60Hz

60Hz

Current Draw:

26A

36A

45A

Circuit Breaker:

40A, 2-Pole

50A, 2-Pole

60A, 2-Pole

* In 40A configuration, the heater will not operate while either jets

pump is running in high speed. Note: pump 2 runs only in high speed.

** In 50A configuration, the heater will not operate while both jet pumps

are running in high speed. Note: pump 2 runs only in high speed.
This is the factory setting.

*** In 60A configuration, the heater will operate while both jet pumps are

running in high speed. Note: pump 2 runs only in high speed.

This manual is related to the following products: