Service

20

Operator’s Manual

AIR OUTPUT, AIR INTAKE AND LINT FILTERS:

1. Remove upper shell. (Fig. 4 or 5)
2. Remove filter end cover screws using 5/16" nut-driver.

(Fig. 8 or 9)

3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter (see "Preventative

Maintenance Schedule").

6. Replace filter end cover.
7. Replace fan guard and upper shell.
IMPORTANT: Do not oil filters.

PUMP PRESSURE ADJUSTMENT:

1. Remove pressure gauge plug from filter end cover

(Fig. 10).

2. Install a pressure gauge.
3. Start space heater (See "Operation"). Allow motor to

reach full speed.

4. Adjust pressure. Turn relief valve to right to increase

pressure. Turn relief valve to left to decrease pressure

(Fig. 11). See specifications below for correct pressure

for each model.

Model:

Pump Pressure:

70

4.7 PSI

115

5.1 PSI

165

5.6 PSI

5. Remove pressure gauge. Replace pressure gauge plug

in filter end cover.

MAINTENANCE (CONTINUED):

(Fig. 9)

Air Intake Filter

Lint Filter

Filter End

Cover

Air Output Filter

Model: AC-70

Air Intake Filter

Filter

End

Cover

Lint Filter

Air Output Filter

Models: AC-115 / 165

(Fig. 8)

Pressure

Gauge

Plug

Relief

Valve

Model: AC-70 Shown

(Fig. 10)

Pressure

Gauge

Model: AC-70 Shown

(Fig. 11)