beautypg.com

John Deere AC-70 User Manual

Page 19

background image

Service

Operator’s Manual

19

WARNING: TO AVOID RISK OF BURN AND

ELECTRICAL SHOCK, NEVER ATTEMPT

TO SERVICE SPACE HEATER WHILE IT IS

PLUGGED IN, OPERATING, OR HOT.

UPPER SHELL REMOVAL:

1. Remove screws along each side of space heater using

5/16" nut-driver. These screws attach upper and lower

shells together. (Fig. 4 or 5)

2. Lift upper shell off.
3. Remove fan guard.

FAN:

IMPORTANT: Remove fan from motor shaft before

removing motor from space heater. The weight of the

motor resting on the fan could damage the fan pitch.

(Fig. 6)

1. Remove upper shell. (Fig. 4 or 5)
2. Use 1/8" allen wrench to loosen setscrew which holds

fan to motor shaft.

3. Slip fan off motor shaft.
4. Clean fan using a soft cloth moistened with kerosene

or solvent.

5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place fan hub flush with

end of motor shaft. (Fig. 7)

7. Place setscrew on flat of shaft. Tighten setscrew firmly

(40-50 inch-pounds / 4.5-5.6 n-m).

8. Replace fan guard and upper shell.

MAINTENANCE (CONTINUED):

(Fig. 4)

(Fig. 5)

Upper Shell

Fan Guard

Screw

Model: AC-70

Fan

Guard

Upper Shell

Screw

Models: AC-115 / 165

Motor Shaft

Setscrew

Fan

Motor

Shaft

Fan

Setscrew

Flush

Motor

(Fig. 6)

(Fig. 7)