Cv-m40 – JAI CV-M40 User Manual
Page 12
![background image](/manuals/133436/12/background.png)
12
CV-M40
TRIG
XSUB
Enlarged
Note : The following charts discribes the delay of the exposure
Exposure time
1.4 ~ 1.5 sec.
Note 1:Sync or HD is not mentioned
Note 2:1H=31.777 S
Note 3:WEN polarity can be chosen at JP22 of I/F board
0.032mS 40mS
Ext.Trig
VIDEO OUT
WEN(positive)
WEN(Negative)
Valid period
Waiting for
Ext.Trigger
Exposure time
3-c) partial scan
A
B
C
7H
1H
Effective readout line
A
B
C
240 line
45H
240H
13H
120 line
66H
120H
17H
60 line
80H
60H
19H
30 line
87H
30H
20H