Jackson HH/GPX User Manual
Page 2
We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
Highway 25E
P. O. Box 1060
Barbourville, KY 40906
Tel: 606-523-9795
Tel: 1-888-800-5672
Fax: 606-523-9196
E-mail: [email protected]
www.jacksonmsc.com
07610-002-66-62 (09/07)
How To Specify -
TempStar™ HH/GPX
moDel no.
SIze
DrAIn
heIght
ShIPPIng Info
DImenSIonS
heIght
wIDth
DePth
weIght
ClASS
Cube
heIght
wIDth
DePth
TempStar™ HH/GPX
76-3/4”
(1949 mm)
25-1/4”
(641 mm)
25-1/4”
(641 mm)
11-3/4”
(298 mm)
420 lbs
(191 kg)
92.5
71.4
cu. ft.
85”
(2159 mm)
44”
(1118 mm)
33”
(838 mm)
DIMENSIONS--STANDARD MODEL
DIMENSION REQUIREMENTS
Minimum Ceiling Height (Recommended)
88” / (2 meters)
Wall Clearance (Minimum)
4” / (102 mm)
Standard Table Height
34” / (864 mm)
Inside Clearance
17-1/4”/ (438 mm)
OPERATING CAPACITY
Racks per Hour
Normal
53
Medium
28
Heavy
19
Extra Heavy
11
OPERATING CYCLE (sec)
Wash
Rinse
Dwell
Total Cycle
Normal
45
15
2
62
Medium
103
15
2
120
Heavy
163
15
2
180
Extra Heavy
283
15
2
300
OPERATING TEMPERATURES
Wash (Minimum)
150˚F / (66˚C)
Rinse (Minimum)
180˚F / (82˚C)
WASH PUMP MOTOR
Wash Pump Motor Horsepower
2 HP
WATER REQUIREMENTS
Inlet Tempterature
40˚F / (4˚C) Rise
140˚F / (82˚C)
70˚F / (21˚C) Rise
110˚F / (60˚C)
Gallons per hour
72.1 / 273 Ltr.
Waterline Size IPS (Minimum-inches)
3/4
Drainline Size IPS (Minimum-Inches)
1-1/2
Flow Pressure (PSI)
15-25
Tank Capacity
Wash Tank
8 Gal. / (30 ltr)
Booster Tank
3 Gal. / (11 ltr)
Pump Capacity (GPM)
73 Gal / (276 ltr)
APPROXIMATE TOTAL LOAD AMPS
AMPS
115V/60HZ/1PH
25
208V/60HZ/1PH
13
230V/60HZ/3PH
13
230V/60HZ/1PH
13
230V/60HZ/3PH
13
GAS REQUIREMENTS
Maximum
Minimum
Natural Gas (Inches-water column)
10.5 / (267 mm)
5.0 / (127 mm)
LP Propane Gas (Inches-water column)
13.0 / (330 mm)
11.0 / 292 mm)
Gas Booster Capacity (BTU)
Input
105,000
Output
84,800
4 [102mm]
4 [102mm]
34 [861mm]
25 [637mm]
8634 [2202mm]
17 [432mm]
C
73 [1856mm]
27 [687mm]
1034 [274mm]
1134 [298mm]
A
312 [92mm]
E
1 [25mm]
734 [194mm]
LEGEND
A - DRAIN 1 1/2” NPT
B - WATER INLET 1/2” NPT
C - ELECTRICAL CONNECTION
D - OUTLET TO BOOSTER
HEATER 3/4” NPT
E - INLET FROM BOOSTER
HEATER 3/4” NPT
All vertical dimensions are +/- 1/2"
due to adjustable bullet feet.
34 [866mm]
A
2514 [639mm]
3 [79mm]
C
1514 [387mm]
1134 [298mm]
B
D
E
18 [456mm]
1634 [426mm]
5 [126mm]
2514 [642mm]
32 [813mm]
3 [77mm]
C