beautypg.com

Pin assignment, 12-pin multi-connector (dc-in/trigger), Bnc connector for analogue monitor video output – JAI CV-M2 User Manual

Page 5: Digital output connector for camera link, Cv-m2

background image

CV-M2

- 4 -

5. Pin Assignment

5.1. 12-pin Multi-connector (DC-IN/Trigger)

Type: HR10A-10R-12PB-01

Pin no.

Signal

Remarks

1

GND

2

+12 V DC input

3

GND

4

Iris Video output

Analogue video for iris control in

continuous mode and RCT mode. *)

5

GND

6

RXD in

7

TXD out

RS 232C. Or via Camera Link

By internal switch HR/CL (Refer to 7.2)

8

GND

9

EEN out

Or via Camera Link

10

Trigger/SG input

TI=1. (Or via Camera Link if TI=0 )
SG=0 trigger input. SG=1 sensor gate contr.

11

Factory use

For factory test

12

GND

(Hirose) male.
(Seen from rear of camera.)

3

4

5

6

7

8

9

10

11

12

1

2

Fig. 2. 12-pin connector.

*) Refer to 5.4.2. for Iris video output. SG = Sensor Gate Control.

5.2. BNC connector for analogue monitor video output

On the BNC connector an analogue video signal (CCIR or EIA) for monitoring is found if OS=2. The
signal can be viewed on a standard monitor as 50 FPS/15.734 kHz 290 lines if MN=1, or 60
FPS/15.734 kHz 240 lines if MN=0. It is non-interlaced and for single channel only. The image
covers the full format, but the resolution is much lower than the digital video output.

5.3. Digital Output Connector for Camera Link

Type: 26 pin MRD connector

13

14

1

26

3M 10226-1A10JL


Fig. 3. Camera Link connector


The digital output signals follow the Camera Link standardized multiplexed signal output
interface. The output driver is NS type DS90CR285, and the receiver is NS type DS90CR286.

The following signals are found on the Digital Output Connector:

SerTC

RXD serial data to camera

(Int. switch HR/CL. Refer to 7.2)

SerTFG

TXD serial data to frame grabber

(Int. switch HR/CL. Refer to 7.2)

CC1

Trigger/Sensor

Gate

input

(TI=0 for CL. SG=1 for Sensor Gate)

CC2

Factory

use

X0 to X3

Camera Link multiplexed data out

Xclk

Camera Link clock. Used as pixel clock.


In the Channel Link X0 to X3 multiplexed signals the following signals are encoded.

D0 – D9

2 x 10 bit video data out for right and left channel.

LVAL

Line VALid. Video line data is valid.

FVAL

Frame VALid. Video frame data is valid.

DVAL

Data VALid. Effective video pixel data is valid

EEN

Exposure

ENable.

(Not specified by Camera Link).

LVAL, FVAL, DVAL polarity is positive. EEN is negative. TRIG is negative as factory setting. TRIG
polarity can be changed by TP. For Camera Link interface principle diagram please check Fig. 7.