6.2.9. Partial scanning vertical timing
Partial scanning has 3 pre-selected vertical centred areas 1/2, 1/4 and 1/8. SC=1 through SC=3.
With SC=3, the start and the height of the partial scanned area can be programmed with 1 line

interval. The start line can be programmed with PS=1 through 1151. The scanned height can be
programmed with PC=50 though 1200. Partial scanning will operate with single or dual channel
output. Partial scan is done by a high-speed dump read out of the areas over and under the area
of interest. This partial scanned area is read out with normal speed. The high-speed dump read
out (Front of Frame and in Back of Frame) is done with a speed 18 times faster for single
channel, and 10 times faster for dual channel.
The figures on the timing diagram below are for 1/2 partial scanning.

LVAL

DVAL

SUB

SG

FVAL

668L( *)

670L( *)

EEN

1 FVAL per i od

Hi gh Speed

Tr ansf er

DATA OUT

OB

Ef f ect i ve Li nes

2L

4 5

59

7

59

6

59

8

60

0

59

9

600L( *)

OB

4L

2L

Bl

ank

31L( *)

31L( *)

1 2 3

0. 5L

Exposur e

Per i od

( *) Var i abl e Number

2L

Fr ont of Fr ame

Back of Fr ame

All figures marked with (*) will change with other partial settings. See table below. 1LVAL = 47.9 µsec (single). 27.3 µsec (dual).

Fig. 23. Partial scanning vertical timing

The following table shows the figures for partial scanning.
The maximum frame rate (FPS) for single and dual channel readout is shown for normal mode.
TR=0. For triggered modes it will be lower, because the accumulation time is added to the read
out time. 1LVAL = 47.9 µsec (single). 27.3 µsec (dual).

Table showing values for the vertical timing.

Single channel output

Frame Start

Frame End

Mode

Scanning


Start
line


Stop
line

OB

[LVAL]

HS

[LVAL]

Effect.
video
[LVAL]

HS

[LVAL]

OB

[LVAL]

Frame
rate
[FPS]



Remarks

SC=0

Full

1

1200

6 0 1200

0

10

17.17

Full scan

SC=1

1/2 partial

301 900 2

17

600 17 6

32.52

Vertical centred

SC=2

1/4 partial

451 750 2

26

300 26 6

57.99

Vertical centred

SC=3

1/8 partial

526 675 2

30

150 30 6

95.77

Vertical centred

SC=4

Programmable

1-1151 50-1200

2

-

50-1200

- 6 -

Start & height program.

Dual channel output

Frame Start

Frame End


Mode


Scanning


Start
line


Stop
line

OB
[LVAL]

HS
[LVAL]

Effect.
video
[LVAL]

HS
[LVAL]

OB
[LVAL]

Frame
rate
[FPS]



Remarks

SC=0

Full

1

1200

6 0 1200

0

10

30.12

Full scan

SC=1

1/2 partial

301 900 2

31

600 31 6

54.67

Vertical centred

SC=2

1/4 partial

451 750 2

46

300 46 6

91.58

Vertical centred

SC=3

1/8 partial

526 675 2

53

150 53 6

138.75

Vertical centred

SC=4

Programmable

1-1151 50-1200

2

-

50-1200

- 6 -

Start & height program.

OB = Optical Black. HS = High-Speed dump read out.