9.2. Specification table

Specifications

CV-M2

Scanning system

Progressive 1216 lines 17 frames/sec.

Pixel clock

40.00 MHz

Line frequency, single output
dual output

20.88 kHz (1916 pixel clock/line). (H = 47.9 µsec)
36.63 kHz (1092 pixel clock/line). (H = 27.3 µsec)

Frame rate, single output
dual output

17.17 frames/sec. (1216 lines/frame)
30.12 frames/sec. (1216 lines/frame)

CCD sensor

1” progressive scan monochrome IT CCD

Kodak KAI-2000M

Sensing area

11.8 (h) x 8.9 (v) mm

Cell size

7.4 (h) x 7.4 (v) µm

Effective pixels

1600 (h) x 1200 (v)

Pixels in video output
Full
1/2 partial
1/4 partial

1/8 partial
Variable scan

1 channel 2 channel
1600 (h) x 1200 (v) 17.17 FPS 30.12 FPS
1600 (h) x 600 (v) 32.52 FPS 54.67 FPS
1600 (h) x 300 (v) 57.99 FPS 91.58 FPS
1600 (h) x 150 (v) 95.77 FPS 138.75 FPS

1600 (h) x 50 (v) to 1200 (v) <167 FPS <208 FPS

Sensitivity on sensor

1.4 lx (100% video out. Min. gain. 0 dB)

0.2 lx (50% video out. Max. gain. 12 dB)

S/N ratio

>50 dB

Video output digital single
digital dual

10 or 8 bit in Camera Link

2 x 10/8 bit in Camera Link

Monitor video output. Analogue

Composite 1.0 Vpp, 75 Ω (50 or 60 FPS. 15.734 kHz)

Iris video output. Analogue

0.7 Vpp, 75 Ω (for iris control)

Gamma

1.0 or 0.45 (Single channel only)

Knee function

Slope 100% to 20%. Knee point adjustable

Gain
Gain range

Manual, potentiometer or remote

-3 to +12 dB (0 – 4095)

Synchronization

Int. X-tal. Ext. random trigger (LVAL synch. or asynch.)

Inputs TTL
Camera Link

Ext. trigger TTL 4 V ±2 V

Ext. trigger

Outputs TTL
Camera Link


EEN output

Pixel clock output

D0-D9 output

DVAL output

LVAL output
FVAL output

EEN output. (Not specified by Camera Link).

Control interface

TXD and RXD via RS 232C

TDX and RDX via Camera Link

Trigger modes

Continuous, Edge pre-select, Pulse width control,

Reset Continuous Trigger, PIV and

EPS Burst (with 5 programmable shutter times)

Read out modes

Single or dual digital output. Analogue output.

Partial scan.

Shutter speed (fixed)

Off, 1/60, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/8000,

1/14,000 second

Pulse width control

1.5 H to ∞. (>72 µsec.) <2 sec. is recommended

Programmable exposure

1.5 H to 1216.5 H (71.9 µsec. to 58.2 msec.) Single channel

1.5 H to 1216.5 H (41 µsec. to 33.2 msec.) Dual channel

Variable scan

50 to 1200 lines

Functions controlled by

RS 232C

Shutter, Trigger, Scanning, Readout,

Trigger input, Video level, Set-up level and Gain

Operating temperature

-5°C to +45°C

Humidity

20 – 80% non-condensing

Storage temp/humidity

-25°C to +60°C/20 – 90% non-condensing

Power

12V DC ± 10%. 6.6 W

Lens mount

C-mount

Dimensions

40 x 50 x 120 mm (HxWxD)

Weight

310g