beautypg.com

System setting screen, Menu (quick) screen, Menu screen settings (continued) – JVC KY-F1030 User Manual

Page 23

background image

E40

Item

AE DISPLAY

FRZ DISPLAY

FRZ CANCEL

TEST PATTERN

LEVEL
When “BAR”/
“IMPULSE”
is selected

MENU RESET

SYSTEM SETTING screen

5. Menu screen settings (continued)

[ ] indicates the factory setting

Set Value

[OFF]

ON

[ON]
OFF

[MANUAL]
AUTO (1s)
AUTO (3s)
AUTO (5s)

OFF

[BAR]

RAMP

IMPULSE

[0.7V]
0.57V

Contents

Used to set whether the ALC, EEI and IRIS values are
displayed on the analog output screen.
OFF:

No on-screen-display

ON:

On-screen-display

Used to set whether the “FREEZE” indicator is shown on
the screen at the time of trigger input.
ON:

Displayed

OFF:

Not displayed

Sets the method for canceling the FREEZE when the
monitor screen is in FREEZE condition when connection
is made through digital output.
MANUAL : Cancelled by trigger input.
AUTO(1s) : Cancelled after 1 second.
AUTO(3s) : Cancelled after 3 seconds.
AUTO(5s) : Cancelled after 5 seconds.
OFF

: Not cancelled.

* When set to “AUTO” or “OFF”, the displayed screen can

be updated by trigger input during the FREEZE condi-
tion.

Sets the test pattern type output when the function set-
ting switch No.1 is set to “ON”.
BAR

: “BAR” pattern is output.

RAMP

: “RAMP” pattern is output.

IMPULSE : “IMPULSE” pattern is output.

Sets the level of the color signal bar output from the KY-
1030’s [ANALOG OUT] connector.
0.7V:

0.7V test signal is output

0.57V:

0.57V test signal is output

Resets all the set values of menus to the initial values.

page E43, Resetting menu settings

E41

MENU (QUICK) screen

[ ] indicates the factory setting

Item

AE LEVEL

IRIS LEVEL

SHUTTER

SPEED
When
“STEP” is
selected

Set Value

–128
–127

[0]


126
127

0
1


[255]

[STEP]

V.SCAN

RANDOM

EEI

OFF

4s
2s
1s

1/2s
1/4s

[1/8s]
1/15s
1/30s
1/60s

1/125s
1/250s
1/500s

1/1000s
1/2000s

Contents

Used to adjust the video level when using auto iris, ALC
and EEI.
Increase the number : raise the level
Decrease the number : lower the level

Used to set the iris level when the IRIS MODE is set to
“MANUAL”.
Increase the number : open iris
Decrease the number : close iris

Used to switch the shutter mode.
STEP:

The shutter speed can be changed with the
[SPEED] item.

V. SCAN:

The shutter speed can be changed with the
[SPEED] item.
Enables more detailed setting than [STEP].

RANDOM: Used to synchronize the CCD accumulation

timing with the trigger input.
The shutter speed can be changed with the
[SPEED] item.

EEI:

Used to automatically change the shutter
speed in accordance with the brightness of the
subject.

OFF:

Fixed at 1/7.5 s.

The shutter speed can be changed when SHUTTER is
set to “STEP”, “V.SCAN” or “RANDOM”.

MEMO

”----“ is displayed when auto iris, ALC, and EEI are all set to