Jacuzzi J - 375 User Manual
Page 18
14
J-300 Series
export J-335, J-345, J-355, J-365 and J-375 Models (50 hz)
230V/20A*
230V/30A**
230V/40A***
Circuit Breaker:
20A
30A
40A
Number of Wires:
3
3
3
Frequency:
50 Hz
50 Hz
50 Hz
Current Draw:
15A
23A
29A
*
In 20A configuration, the heater will not operate while either jets
pump is running in high speed. This is the factory setting. Note:
pump 2 runs only in high speed.
** In 30A configuration, the heater will operate while one jets pump
is running in high speed. Note: pump 2 runs only in high speed.
*** In 40A configuration the heater will operate while both jets pumps
are running in high speed.
export J-315 and J-325 models (50 Hz)
230V/20A*
230V/30A**
Circuit Breaker:
20A
30A
Number of Wires:
3
3
Frequency:
50 Hz
50 Hz
Current Draw:
15A
21A
* In 20A configuration, the heater will not operate while the jets
pump is running in high speed. This is the factory setting.
** In 30A configuration, the heater will operate while one jets pump
is running in high speed.
14