2 known issues from screenos 5.0.0r8 – Juniper Networks NETSCREEN 208 User Manual
Page 33

Juniper Networks
NetScreen Release Notes
ScreenOS 5.0.0r9-FIPS
P/N 093-1638-000, Rev. A
Page 33 of 42
• 03504 – The value of the sysUpTime variable from an SNMP query
incorrectly displays as more than 497 days.
• 03495 – When the device drops packets after you issued the set flow tcp-
syn-check command, ScreenOS does not log the drop instances.
• 03492 – When you enable the URL filtering service, the device drops HTTP
Move packets.
• 03484 – If an interface rapidly repeatedly disconnects and reconnects, the
number of OSPF routes drops below the number of expected routes causing
the OSPF routing instance to clear its route table.
• 02751 – After resubmitting the ICMP destination unreachable setting
through the device, the packet passes through the device, but the device
generates the following log message:
Apr 21 20:07:41 10.155.132.247 Iapetus: NetScreen
device_id=Iapetus system-notification-00257(traffic):
start_time="2004-04-21 21:12:34" duration=0 policy_id=22
service=icmp proto=1 src zone=Trust dst zone=Trust
action=Permit sent=0 rcvd=0 src=69.91.47.31 dst=128.157.5.23 icmp
type=8 session_id=19178
5.3.2 Known Issues from ScreenOS 5.0.0r8
• 03153 – When you attempt to download plugin and main program files in
one file, the system generates errors.
• 03065 – When you download the asset recovery log from the WebUI, it
appears with the incorrect date and time with the date being seven years
different than the correct date.
• 02927 – Devices upload HTTP traffic very slowly after you enable both the
anti-virus and URL filtering options in a policy on the device.
• 02869 – A Juniper NetScreen-5GT cannot deliver mail and the POP3 (Post
Office Protocol 3) session times out when the device runs an anti-virus scan
on an SMTP or POP3 policy.
• 02297 – An anti-virus scan drops connections with selected HTTP and
HTTPS sites.
• 02266 – When you make one configuration change on a device, the device
sometimes sends out more than one entry associated with that change to
both the syslog and WebTrends servers.
• 01237 – In an NSRP configuration of two Juniper NetScreen-200 devices,
you cannot save a device configuration from flash memory on the device to
slot 1.