Sonet/sdh oc48c/stm16 pic (quad-wide) – Juniper Networks M20 User Manual
Page 30

SONET/SDH OC48c/STM16 PIC (Quad-Wide)
■
JUNOS 4.1 and later
Software release
■
One OC48 port
■
Power requirements: 0.86 A @ 48 V (41.4 W)
Description
■
Multiplexing and demultiplexing
■
Rate policing on input
■
Rate shaping on output
■
Packet buffering, Layer 2 parsing
Hardware features
■
SONET/SDH framing
■
Link aggregation
■
Alarm and event counting and detection
■
Dual-router automatic protection switching (APS)
■
Multiprotocol Label Switching (MPLS) fast reroute
■
Encapsulations:
■
High-Level Data Link Control (HDLC)
■
Frame Relay
■
Circuit cross-connect (CCC)
■
Translational cross-connect (TCC)
■
Point-to-Point Protocol (PPP)
Software features
30
■
SONET/SDH OC48c/STM16 PIC (Quad-Wide)
M20 Internet Router PIC Guide: End-of-Life PICs