Chapter 3. Diagnostics

23

Ethernet teaming messages:

0x0F

Explanation:

Could not allocate enough memory for other structures. Action:

1.

From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.

2.

Select your IBM Ethernet adapter from the list.

3.

Select Properties -> Advanced.

4.

Lower the value for the resource named in the message.

0x10

Explanation:

Did not find any Ethernet controllers. Action: Using the Configuration/Setup utility,

make sure that Ethernet is enabled.

0x11

Explanation:

Multiple Ethernet controllers found, but none matched the required ID. Action:

Using the Configuration/Setup utility, make sure that Ethernet is enabled.

0x13

Explanation:

Did not find any Ethernet controllers that matched the required subven/subdev.

Action:

Using the Configuration/Setup utility, make sure that Ethernet is enabled.

0x16

Explanation:

Single adapter found but multiple instances tried to load. Action: Using the

Configuration/Setup utility, make sure that Ethernet is enabled, and that the slot containing the
IBM Netfinity 10/100 Ethernet Adapter or the IBM 10/100 Etherjet PCI adapter is enabled.

0x17

Explanation:

Slot parameter not specified in the registry. Action: Remove the adapter driver and

reinstall it. If the problem persists, call for service.

All other 4-
character
hexadecimal
codes

Action:

Call for service.

Table 7. NDIS (Windows NT or Windows 2000) driver teaming messages for the Ethernet controller.

Event ID

Type

Description

01

Error

Explanation:

Team Name and physical adapter name are the same. This is

an invalid configuration. Action: Reconfigure the adapter team by double-
clicking the PROSet icon in the control panel.

02

Error

Explanation:

Unable to allocate required resources. Action: Free some

memory resources and restart.

03

Error

Explanation:

Unable to read required registry parameters. Action:

Reconfigure the adapter team by double-clicking the PROSet icon in the
control panel.

04

Error

Explanation:

Unable to bind to physical adapter. Action: Reconfigure the

adapter team by double-clicking the PROSet icon in the control panel.

05

Error

Explanation:

Unable to initialize an adapter team. Action: Reconfigure the

adapter team by double-clicking the PROSet icon in the control panel.

06

Informational

Explanation:

Team nn. Primary adapter is initialized. Action: None.

07

Informational

Explanation:

Team nn. Secondary adapter is initialized. Action: None.

08

Informational

Explanation:

Team nn. Virtual adapter or Team is initialized. Action: None.

09

Informational

Explanation:

Team nn. Primary adapter is switching over. Action: None.

10

Warning

Explanation:

Team nn. Adapter link down. Action: Make sure the adapter

is functioning properly.

11

Informational

Explanation:

Team nn. Secondary adapter took over. Action: None.

Table 6. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet controller.

Error code (hex)

Description