beautypg.com

Electrical requirements, Environmental requirements, Electrical requirements environmental requirements – IBM 24R9718 IB User Manual

Page 58

background image

14

equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.

Electrical Requirements

Environmental Requirements

NOTE: In the case of non-uniform air flow, the velocity at any point must meet or exceed 150 LFM.

Table 3-2: EMC/EMI Certifications

Certification

FCC: Title 47 CFR 47 Part 15, Subpart B, Class A

ICES-003 Issue 2

CE: EN55022:1998 and EN55024:1998

VCCI: V3/2000.04, Class A

C-Tick: AS/NZS 3548:1995, Am.1:1997, Am.2:1997

BSMI

MIC Notice No. 1996-78

GOST 29216-91

Table 3-3: DC Supply Requirements

Area

Requirement

DC Supply Voltage

12.0 Volts

DC Supply Current

2.1 Amps

Table 3-4: Environmental Requirements

Area

Requirement

Module Operating Temperature

0 to +55 degrees C (module inlet)

Forced Air Cooling: Rate

8 CFM minimum

Forced Air Cooling: Inlet Velocity

315 LFM average

Module Non-Operating Temperature -40 to +70 degrees C

Operating Altitude

0 to 4000 meters

Non-Operating Altitude

0 to 11,000 meters

Operating Humidity

5% to 85% non-condensing

Non-Operating Humidity

5% to 95% non-condensing

Operational Shock

3.5G for 3 mSec.

Operational Vibration

0.27G at 5Hz to 500Hz for 30 minutes

Storage Shock

50G with a velocity change of 3454 mm/sec squared

Storage Vibration

0.5G at 2Hz to 200Hz for 15 minutes