beautypg.com

0 reliability, 1 error detection, 2 data reliability – IBM C2B 2.25 Brick On Sled carrier 128-pin HPC User Manual

Page 73: 3 seek error rate, 4 power on hours examples

background image

USER RESPONSIBLE F O R V E R I F Y I N G VERSION A N D COMPLETENESS

O E M F U N C T I O N A L SPECIFICATION ULTRASTAR X P (DFHC) SSA M O D E L S 1.12/2.25 GB - 1.0" H I G H

6.0 Reliability

Note: The reliability projections are based on the conditions stated below. All of the SSA models will meet
the projections as long as reliability operating conditions are not exceeded.

6.1 Error Detection

Error reporting

99%

All detected errors excluding interface and BATs #1 (Basic Assur-
ance Test) errors

Error detection

99%

FRU isolation = 100%

To the device when the "Recommended Initiator Error Recovery
Procedures" in the Ultrastar XP ( D F H C ) S S A Models Interface
Specification
are followed.

N o isolation to sub-assemblies within the device are specified.

6.2 Data Reliability

Probability of not recovering data

10 in 10

15

bits read

Recoverable read errors

10 in 10

13

bits read (measured at nominal D C conditions and room

environment with default error recovery — QPE

**

)

Probability of miscorrecting unrecoverable data

Note: Eighteen bytes of ECC and two bytes of L R C are provided for each data block.

6.3 Seek Error Rate

The drives are designed to have less than 10 errors in 10,000,000 seeks. In the field, a seek error rate of 40 in
100, 000 seeks will trip P F A (Predictive Failure Analysis) error.

The drives are designed to achieve Soft Seek Error rate of 1 error in 100,000,000 seeks.

6.4 Power On Hours

Examples:

Maximum power on hours (with minimum power on/off cycles)

43,800 hours for life based on:

- 5 Power on/off cycles per month

- 730 power on hours per month

Nominal power on hours (with nominal power on/off cycles)

30,000 hours for life based on:

**

Refer to Ultrastar X P ( D F H C ) S S A Models Interface Specification for the definition of Q P E (Qualify Post Error).

Source filename=RELIABLE

IBM Corporation

Page 73 of 87