Table 3. Light path diagnostics (continued)
Lit LED
Cause
Action
Power module
System error
A critical error has occurred in the power
module.
Reseat the power module. If the problem
remains, replace the module.
If your BladeCenter unit has a redundant
module for this power module, the BladeCenter
unit continues to function using the redundant
module.
Blower module
System error
The blower has failed or is operating too
slowly.
Reseat the blower module. If the problem
remains, replace the blower module as soon
as possible, to regain cooling redundancy.
The BladeCenter unit continues to function.
The redundant blower module provides cooling
to the BladeCenter unit and blade servers.
I/O module
System error
A critical error has occurred in the I/O module.
Reseat the I/O module. If the problem remains,
replace the module.
58
BladeCenter Type 8677: Installation and User’s Guide
- I5 (59 pages)
- 2274 (183 pages)
- X3650 (18 pages)
- P5 570 (82 pages)
- 6E1 (40 pages)
- 704 (348 pages)
- SG24-4576-00 (235 pages)
- SCOD-3ZVQ5W (548 pages)
- LOTUS TEAM WORKPLACE 6.5.1 (17 pages)
- HANDBOOK 150 (286 pages)
- 6C4 (233 pages)
- 6059 (248 pages)
- 6644 (100 pages)
- 2283 (96 pages)
- 755 (47 pages)
- PANEL1173-841 (80 pages)
- G325-2585-02 (90 pages)
- BladeCenter T Type 8730 (180 pages)
- PC Server/Enterprise Racks 9QX (208 pages)
- X3620 M3 (19 pages)
- NETVISTA X40 6643 (120 pages)
- 440 (202 pages)
- xSeries 235 (66 pages)
- 47AE - 410168 (27 pages)
- TotalStorage DS6000 Series (406 pages)
- 310E (120 pages)
- NETVISTA 8319 (52 pages)
- A40P TYPE 6841 (148 pages)
- POWER 710 (45 pages)
- LCD PC (50 pages)
- 525 (33 pages)
- N2800e (82 pages)
- 6345 (214 pages)
- 2197 (208 pages)
- 4194 (84 pages)
- V7.2 (41 pages)
- SC34-6814-04 (953 pages)
- 6268 (53 pages)
- Enterprise Server H80 Series (230 pages)
- 6.00E+01 (42 pages)
- G544-5774-01 (56 pages)
- z/OS (88 pages)
- Aptiva 2140 (212 pages)
- GC23-7753-05 (56 pages)