beautypg.com

Heavy duty cleaning procedure, Ƽ warning, Caution – Invacare 3600XL User Manual

Page 30

background image

SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING

Side Entry Whirlpool Tub

30

Part No 1118387

Heavy Duty Cleaning Procedure

ƽ WARNING

The disinfectant dispensing system has been factory tested and calibrated for use with Invacare
disinfectant. The use of any disinfectant with a dilution ratio (½ oz. per gallon) or viscosity level different
than that of Invacare disinfectant will result in an improper mixture of disinfectant and water. This may
cause your system to be improperly disinfected - or in some instances, not disinfected at all. If using any
disinfectant with a dilution ratio or viscosity level different than that of Invacare disinfectant or if
switching from one type of disinfectant to another type, the disinfectant flowmeter must be calibrated
before performing this procedure. Refer to Calibrating the Disinfectant Flow Meter on page 31.
ALWAYS wear rubber gloves, an apron and face shield protection during disinfecting, cleaning and
rinsing procedures. In case of eye or skin contact, follow procedures on disinfectant container.

CAUTION

NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The
use of these types of cleaners will make the gel-coat finish of your tub scratched and dull. NEVER use
cleaners containing iodine, bromine, Betadine or methylene blue. The use of these types of cleaners
will cause the tub to stain. Never use cleaners containing bleach. Use of these types of cleaners will
dry out the rubber seals and gaskets and the tub will not function properly.
Before starting the whirlpool pump, the water level must be completely above the whirlpool jets.
Otherwise damage to the motor/pump will result.

In addition to disinfecting your tub after every use, you will need to perform this procedure approximately once 
every 80‐150 baths.
1.

Clean the entire surface of the tub to remove visible tissue 
residue and fluid.

2.

Rinse the inside surface of the tub with the shower/massage 
wand on the spray setting.

3.

Rotate the water temperature valve to adjust the water 
temperature to approximately 105

o

 F.

NOTE: This will maximize the cleaning solutionʹs ability to clean and 
disinfect the system.
4.

Close the drain.

5.

Make sure the whirlpool jets are open.

6.

Fill the tub one inch above the highest whirlpool jets.

7.

Add the Invacare Heavy Duty Cleaner to the water in the 
tub. Refer to the chart for the proper amount.

8.

Spray pre‐mixed Invacare Heavy Duty Cleaner on the 
remaining surfaces.

9.

Press the whirlpool on/off button to turn on the whirlpool 
pump and let the pump run for 60 seconds.

10. Turn off the pump and allow the heavy duty cleaner/water 

solution to remain in the tub for 10 minutes. 

11. During this ten‐minute waiting time, take a long handled 

brush and thoroughly scrub all interior surfaces of the tub.

12. Open the drain to allow the heavy duty/water solution to 

drain from the tub. 

13. Use the shower/massage wand on the pulse setting and 

direct the spray into both whirlpool jets to back flush until 
the water discharging from the whirlpool inlet is clear.

14. Rinse the tub thoroughly with the shower wand on the spray setting.
15. Check the tub for damage and to ensure all surfaces of the tub are clean and that no visible residue 

remains. If residue is found, repeat STEPS 13 and 14

TUB

MODEL

NUMBER

WATER REQUIRED

TO COVER JETS

(GALLONS)

INVACARE

HEAVY DUTY

CLEANER

REQUIRED (OZ)*

2800

10

40

2001

32

128

3700

30

120

3750

30

120

3800

30

120

3600

30

120

3650

48

192

3600XL

48

192

2300

25

100

3300

30

120

4300

35

140

4300HL

35

140

5300

52

208

5300HL

52

208

6300

50

200

6300ADH

50

200

4400SS

48

192

5400SS

50

200

*NOTE: If using non‐Invacare heavy duty 
cleaner, refer to the instructions supplied with the 
cleaner to determine the proper amount required.

This manual is related to the following products: