beautypg.com

Onboard fdc controller, Uart mode select, Hot key power on – Intel SBC-776 User Manual

Page 73: Rxd, txd active, Ur2 duplex mode, Use ir pins

background image

64 SBC-776 User Manual

Onboard FDC Controller

Select Enabled if your system has a floppy disk controller (FDC)
installed on the system board and you wish to use it. If you install
an add-in FDC or the system has no floppy drive, select Disabled
in this field.

UART Mode Select

Select an operating mode for the second serial port:

Normal

RS-232C serial port

IrDA 1.0

Infrared port compliant with IrDA 1.0

specification

IrDA SIR

IrDA-compliant serial infrared port

IrDA MIR

1 MB/sec infrared port

IrDA FIR

Fast infrared standard

ASK IR

Amplitude shift keyed infrared port

SCR

Hot Key Power On

Simply pressing on the pre-selected keyboard key the system will
power on.

RxD, TxD Active

Consult your IR peripheral documention to select the correct

setting of the TxD and RxD signals

UR2 Duplex Mode

Select the value required by the IR device connected to the IR prot.
Full-duplex mode permits simultaneous two-direction transmission.
Half-duplex mode permits transmission in one direction only at a

time. If no infrared port is present in the system, select disabled.

Use IR Pins

Consult your IR peripheral documentation to select the correct