IDEAL INDUSTRIES 61-320 User Manual
Page 6

Page 4
Measurement Characteristics
Accuracy is
±
(% reading + number of digits) at 23
°
C
±
5
°
C, less than 80% R.H.
DC Volts
Range
Resolution
Accuracy
Over voltage
protection
600.0mV 100µV
6.000V
1mV
60.00V
10mV
600.0V
100mV
1000V
1V
±(0.5% + 2dgt)
1000V rms
AC Volts
Range
Resolution
Accuracy
Over voltage
protection
600.0mV 100µV
Unspecified
6.000V
1mV
60.00V
10mV
600.0V
100mV
750V
1V
±(0.9% + 5dgt)
50Hz ~ 500Hz
*
1000V rms
Input Impedance: 10MΩ // less than 100pF.
CMRR / NMRR: (Common Mode Rejection Ratio)
(Normal Mode Rejection Ratio)
V
AC
: CMRR > 60dB at DC, 50Hz / 60Hz
V
DC
: CMRR > 100dB at DC, 50Hz / 60Hz
NMRR > 50dB at DC, 50Hz / 60Hz
AC Conversion Type: 61-320: Average sensing rms indication.
61-322 / 61-324: AC conversions are ac-coupled, true rms responding, calibrated to
the sine wave input.
* The basic accuracy is specified for sine wave below 4000 counts. Over 4000 counts, need to add 0.6% to the
accuracy for non-sine waves below 2000 counts, refer to the following for accuracy:
Crest Factor (C.F.):
+1.5% addition error for C.F. from 1.4 to 3
+3.0% addition error for C.F. from 3 to 4 where C.F.=Peak / RMS
Form number TM61320-2-4
Rev 2 September 2002