3power management, 1 power measurement support, Rv p – Intel ATOM US15W User Manual
Page 21
Power Management
User’s Manual
21
Document Number: 320264
3
Power Management
3.1
Power Measurement Support
Power measurement resistors are provided to measure the power on many of the
subsystems.
Table 5. Power Measurement Resistor
Feature
Value
Tolerance 1%
Value 10
mΩ
NOTE: Intel recommends that larger (~10 mΩ) resistors be stuffed for greater accuracy.
Power on a particular subsystem is calculated using the following formula:
Equation 1.
R
V
P
2
=
R = value of the sense resistor (typically 0.01 Ω)
V = the voltage difference measured across the sense resistor.
Use a high precision digital multi-meter tool such as the Agilent 34401A digital multi-
meter. Refer to
Table 6
for a comparison of a high-precision, digital multi-meter
(Agilent 34401A) versus a precision, digital multi-meter (Fluke 79).
Table 6. Digital Multi-Meter Comparison
Example System
Sense Resistor Value
0.01 Ω
Voltage Difference Across Resistor
1.492 mV (149.2 mA)
Calculated Power
0.223 mW