Chapter 3. Availability, investment protection, and expansion

21

3.2.1 Light Path diagnostics

The Models 6C1 and 6E1 are the first IBM UNIX servers that implement Light Path
diagnostics technology. Light Path LEDs provide an obvious and intuitive means to positively
identify the failing Field Replaceable Unit (FRU) through a path of light emitting points,
starting on the exterior of the system (System Attention LED), located on the front of the
system (also on the rear of rack mounted 6C1), and ending with a LED at or near the failing
FRU. Correlation of the LED layout and the failing component is straightforward. Intermediate
light points lead you to the area or subassembly of the machine where the failing FRU is
located.

Initially, for the Models 6C1 and 6E1, the fault LEDs will be implemented with only two LED
states (ON and OFF).

Attention and Light Path LEDs

The attention and Light Path LEDs provide a means to identify failing components in your
server. Attention LEDs are located on the front and rear of the system to make it easy for an
on-site technician to quickly locate the system requiring attention.

When a failing component is detected in your server, the attention LED is turned on. To
further help you identify the failing component, go to the indicator panel inside the server and
check which LEDs are lit on the indicator panel. After you have replaced the failing part you
have to manually turn off the attention light using the service processor submenu or invoke
the online diagnostics with the

diag

command (as discussed in the following).

Enter

diag

and press Enter to continue. Then from the Function Selection main menu select

Task Selection (Diagnostics, Advanced Diagnostics, Service Aids, etc.). Scroll down and
select Log Repair Action. Select the device that was repaired (if the device is not listed,
select sysplanar0). This will turn off the attention and Light Path LEDs. For more detailed
information refer to the IBM

^

pSeries 610 Models 6C1 and 6E1 User’s Guide,

SA38-0598.

System indicator panel

Figure 3-1 shows where you can find the system indicator panel in a Model 6C1.

Figure 3-1 System indicator panel in a Model 6C1