background image

Flake Ice Machines

Refrigeration System

Page

F12

Receiver
If the system has a remote condenser, the refrigerant will enter a receiver before
passing through the filter drier. The receiver holds reserve liquid refrigerant
during the freeze cycle. The receiver also stores liquid refrigerant during the off
cycle.



Refrigerant
Refrigerant in a high-pressure liquid form is fed to an expansion valve where the refrigerant is
reduced to a low-pressure liquid. Under this low pressure, the liquid will absorb heat from the
evaporator causing the liquid to change to a vapor. This vapor is the drawn into the
compressor where the temperature and pressure of the vapor are increased. The high
temperature, high pressure vapor flows to the condenser where the heat is removed, causing
the vapor to return to the liquid form, making the refrigerant ready to flow back to the
evaporator to pick up more heat.

Most Ice-O-Matic ice machine use R134a or R404a refrigerant. Always check the serial
number data plate for the proper type of refrigerant and the amount used in the machine you
are servicing.

R404a and R134a are both HFC refrigerants, which result in no ozone depletion factor.
R404a cylinders are orange in color, R134a cylinders are light blue in color.

Important: When discharging refrigerant from an icemaker, recover as much of the
refrigerant as possible with a recovery device or some other means to prevent the
refrigerant from entering the atmosphere.