beautypg.com

Flake ice machines refrigeration system – Ice-O-Matic EMF Series User Manual

Page 45

background image

Flake Ice Machines

Refrigeration System

Page

F4

Refrigerant Pressures (Continued)
The operating pressures for models utilizing the Sporlan thermostatic expansion valve are
listed below.

SPORLAN Manufactured Expansion Valve

Model

Air

Water

Suction

Discharge Pressure PSIG

Number

Temp °F

Temp °F

Pressure PSIG

192 LAC

240 LAC

EF250/255

70°F

50°F

52-56

240

90°F

70°F

55-59

310

EMF405A

70°F

50°F

50-53

225

90°F

70°F

54-57

285-290

EF/EMF450A

70°F

50°F

49-53

260

90°F

70°F

53-57

320-325

EMF450W

70°F

50°F

50-52

250

90°F

70°F

52-53

250

EMF705A

70°F

50°F

38-40

270

90°F

70°F

42-45

345-350

EF/EMF800A

70°F

50°F

45-48

275

90°F

70°F

49-51

340-345

EMF800W

70°F

50°F

41-43

250

90°F

70°F

41-43

250

EMF1005A

70°F

50°F

38-42

295-300

90°F

70°F

42-45

328-333

EMF1106A

70°F

50°F

41-43

270

90°F

70°F

43-47

320-325

EMF1106W

70°F

50°F

38-39

250

90°F

70°F

38-40

250

EMF1106R

70°F

50°F

39

215-220

257

90°F

70°F

41-43

273-278

268

EMF2306A

70°F

50°F

37-38

275

90°F

70°F

42

330-335

This manual is related to the following products: