Flake ice machines refrigeration system – Ice-O-Matic EMF Series User Manual
Page 45
Flake Ice Machines
Refrigeration System
Page
F4
Refrigerant Pressures (Continued)
The operating pressures for models utilizing the Sporlan thermostatic expansion valve are
listed below.
SPORLAN Manufactured Expansion Valve
Model
Air
Water
Suction
Discharge Pressure PSIG
Number
Temp °F
Temp °F
Pressure PSIG
192 LAC
240 LAC
EF250/255
70°F
50°F
52-56
240
90°F
70°F
55-59
310
EMF405A
70°F
50°F
50-53
225
90°F
70°F
54-57
285-290
EF/EMF450A
70°F
50°F
49-53
260
90°F
70°F
53-57
320-325
EMF450W
70°F
50°F
50-52
250
90°F
70°F
52-53
250
EMF705A
70°F
50°F
38-40
270
90°F
70°F
42-45
345-350
EF/EMF800A
70°F
50°F
45-48
275
90°F
70°F
49-51
340-345
EMF800W
70°F
50°F
41-43
250
90°F
70°F
41-43
250
EMF1005A
70°F
50°F
38-42
295-300
90°F
70°F
42-45
328-333
EMF1106A
70°F
50°F
41-43
270
90°F
70°F
43-47
320-325
EMF1106W
70°F
50°F
38-39
250
90°F
70°F
38-40
250
EMF1106R
70°F
50°F
39
215-220
257
90°F
70°F
41-43
273-278
268
EMF2306A
70°F
50°F
37-38
275
90°F
70°F
42
330-335