Flake ice machines refrigeration system – Ice-O-Matic EMF Series User Manual
Page 44

Flake Ice Machines
Refrigeration System
Page
F3
Refrigerant Pressures (Continued)
The operating pressures for models utilizing the Alco thermostatic expansion valve are
listed below.
ALCO Manufactured Expansion Valve
Model
Air
Water
Suction
Discharge Pressure PSIG
Number
Temp °F
Temp °F
Pressure PSIG
192 LAC
240 LAC
EMF2306R
90°F
70°F
40
265
266
70°F
50°F
35
217
260
-20°F/50°F
40°F
33
200
263
120°F/110°F
100°F
45
365
355
EMF2306W
90°F
70°F
38
250
70°F
50°F
37
250
50°F
40°F
36
250
110°F
100°F
42
250
EMF405A
90°F
70°F
56
274
70°F
50°F
53
215
50°F
40°F
36
158
110°F
100°F
61
352
EMF450A
90°F
70°F
56
290
70°F
50°F
52
222
50°F
40°F
51
131
110°F
100°F
57
374
EMF450W
90°F
70°F
50
250
70°F
50°F
48
250
50°F
40°F
46
250
110°F
100°F
54
250