4.2 Replacement of the battery module

4. Maintenance

Removal of the battery module

When replacing batteries, use the Battery Replacement Chart below to determine the correct battery.
This operation may be carried out with the UPS supplying power to the load.

Safety rules

Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and required
precautions. Keep unauthorized personnel away from batteries. Batteries constitute a danger (electrical shock,
burns). The short-circuit current may be very high. Precautions must be taken for all handling:

remove all watches, rings, bracelets and any other metal objects;

use tools with insulated handles.

A - Unclip the small plate with the MGE

logo on the front panel of the UPS.

B - Remove the two screws.
C - Remove the left-hand side of the front

panel by pulling it slightly up and then for-
ward.

D - Disconnect the battery module by

pulling apart the connectors (never pull on
the cables).

Tower models

D

Battery Replacement Chart

Component

Manufacturer

Manufacturer’s
Catalog Number

6V 7,2A Bat (in 800VA Rack)

Panasonic

LC-R067R2CH1

12V 7,2A Bat (in 800VA Tower)

CSB

GP1272F2

6V 9A Bat (in 1100VA Rack and 500VA)

Panasonic

UP-RW0645CH1

12V 9A Bat (in 1100VA Tower)

CSB

HR1234wF2