5. 10-pin plug plg8 information, 6. 7-pin plug plg1 information, 7. 10-pin plug and shielding gas connections – Miller Electric DS-2 User Manual
Page 12

OM-197 509 Page 8
3-5.
10-Pin Plug PLG8 Information
Pin
Pin Information
A
24 volts ac for gas valve control when triggered or purging gas.
B
+15 volts dc with gun trigger open; 0 volts dc with gun trigger closed.
C
Circuit common.
D
0 to +10 volts dc output from min to max of Output Command control R1.
E
+10 volts dc input.
F
0 to +10 volts dc output from min to max of Wire Speed control R2
G
+15 volts dc with Jog switch S3 open; 0 volts dc with switch closed.
H
Motor positive (+), (0 to +24 volts dc input to wire drive motor M1 with respect to pin I.)
I
Motor negative (–).
J
Not used
3-6.
7-Pin Plug PLG1 Information
Pin
Pin Information
1
Not used.
2
Not used.
3
Circuit common.
4
0 to +10 volts dc output from min to max of Output Command control R1.
5
+10 volts dc input.
6
0 to +10 volts dc output from min to max of Wire Speed control R2
197 504
7
+15 volts dc with Jog switch S3 open; 0 volts dc with switch closed.
1
Gas Hose (Customer
Supplied)
Connect to gas supply.
2
10 Pin Plug PLG8
Use plug to make connection to
welding power source.
3
Weld Cable w/Quick Connect
3-7.
10-Pin Plug And Shielding Gas Connections
Ref. St–802 483-A
Tools Needed:
1
11/16 in
2
3