1.1

Test Equipment

Table 1-1

lists test equipment required to service the CP150/CP200 Radios.

Table 1-1. Recommended Test Equipment

Motorola Part No.

Description

Characteristics

Application

R2600 series

System analyzer

This item will substitute for
items with an asterisk (*)

Frequency/deviation meter and
signal generator for wide-range
troubleshooting and alignment

*R1074A

Fluke 87 digital multi-
meter

True RMS metering,
200 kHz frequency
counter, 32-segment bar
graph with backlit display

Digital voltmeter is recom-
mended for AC/DC voltage and
current measurements

Fluke 85 RF probe

500 MHz, 30 VAC max

Use with Fluke 87 digital multi-
meter for RF voltage measure-
ments.

*R1377A

AC voltmeter

1 mV to 300 mV, 10 mega-
ohm input impedance

Audio voltage measurements

R1611A

Dual channel
100 MHz oscillo-
scope (Agillent)

Two-channel, 100 MHz
bandwidth, 200 M sample
rate/sec, 2 MB memory/
channel

Waveform measurements

S1339A

RF millivolt meter

100

µV to 3V RF, 10 kHz to

1 GHz frequency range

RF level measurements

*R1013B or

*R1370A

SINAD meter or

SINAD meter with
RMS

Without RMS audio voltme-
ter or
With RMS audio voltmeter

Receiver sensitivity measure-
ments

This manual is related to the following products: