6. Grasp the starter grip (Figure 12) and slowly pull it out. The

resistance becomes the hardest at a certain position, corre-
sponding to the compression point. Pull the starter grip briskly
and smoothly for starting.

7. If the engine has started, and the choke lever was moved to

the

CLOSED

position to start the engine, gradually move the

choke lever lever to the

OPEN

position as the engine warms

up.If the engine has not started repeat steps 1 through 6.

Figure 12. Starter Grip

8. Before the pump is placed into operation, run the engine for

several minutes. Check for fuel leaks, and noises that would
associate with a lose component.

9. To begin pumping, place the throttle lever (Figure 14) in the

"

RUN" position.

Figure 13. Choke Lever (Open)

Figure 14. Throttle Lever (Run)

Stopping The Engine

Normal Shutdown

1. Move the throttle lever to the IDLE position (Figure 15) and

run the engine for three minutes at low speed.

Figure 15. Throttle Lever (Idle)

2. After the engine

cools

, turn the engine ON/OFF switch to the

OFF” position (Figure 16).

3. Place the

fuel shut-off lever

(Figure 17) in the OFF

position.

Figure 16. Engine ON/OFF Switch (OFF)

Figure 17. Fuel Valve Lever (OFF)

Emergency Showdown

1. Move the throttle lever quickly to the

IDLE

position, and place

the engine ON/OFF switch in the

OFF

position.

ALWAYS run engine at

full speed while pumping.

CAUTION - Maximum Engine Speed