beautypg.com

Qp-402h — pre-setup (pump) – Multiquip MQ Multiquip Centrifugal Pump qp-402h User Manual

Page 17

background image

QP-402H CENTRIFUGAL PUMP — OPERATION AND PARTS MANUAL— REV. #1 (04/02/08) — PAGE 17

Pre-Setup (Pump)

1.

Read safety instructions at the
beginning of manual.

2. Place pump as near to water as

possible, on a firm flat, level surface.

3. To prime pump, remove fill cap (Figure 2) and fill pump casing

with water. If the pump casing is not filled with water before
starting, it will not begin pumping.

QP-402H — PRE-SETUP (PUMP)

4. Check for

leaks

between pump and engine. If water is leaking

between the pump and engine housing, the seal inside the
pump may be worn or damaged. Continued operation of the
pump is not recommended. Further usage of the pump under
these conditions may cause severe water damage to engine.

Hoses and Clamps

1. Check that all hoses are

securely

attached to the pump.

Make certain suction hose (Figure 2) does not have any air
leakage. Tighten hose clamps and couplings as required.

2. It is recommended that 2 clamps be used when securing the

suction hose to the inlet side (suction) of the pump.

3. Remember suction hoses must be

rigid

enough not to

collapse when the pump is in operation.

4. Check that the discharge hose (Figure 2) is not restricted.

Place hose so that it lays as straight as it is possible on the
ground. Remove any twists or sharp bends from hose which
may block the flow of water.

NOTE

Suction and discharge hoses are
available from Multiquip. Contact
your nearest dealer for more
information.

5.

The discharge hose is usually a

collapsible (thin-walled)

hose, however if a thin-walled discharge hose is not avail-
able, a rigid suction hose can be substituted in its place.

6.

Make sure the

suction strainer (Figure 2) is clean and

securely attached to the water end of the suction hose. The
strainer is designed to protect the pump by preventing large
objects from being pulled into the pump.

Pump casing

must be filled with water before using pump.

Otherwise pump will not be able to begin pumping.

CAUTION - Pump Casing

DO NOT open

fill cap if pump is hot!

Water inside may be under pressure.
The possibility exists of scalding,
resulting in severe bodily harm.

WARNING - High Pressure

The strainer should be positioned so it will remain completely
under water. Running the pump with the strainer above
water for long periods can damage the pump.

CAUTION - Strainer

CAUTION - Flammable Fluids-Chemicals

DO NOT pump flammable fluids, corrosive chemicals or fluids
containing toxic substances. These fluids can create potentially
dangerous health and environmental hazards. Contact local
authorities for assistance.

CAUTION - Mechanical Seal

This pump uses a water-cooled

mechanical

seal

to prevent

water from seeping into the engine. The passage of water
through the pump casing lubricates the seal and prevents it
from overheating.

NEVER!

operate the pump without water

in the casing as this will cause damage to the mechanical
seal.