7-2. Optional Generator Power Receptacles
Y If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.
.
Generator power decreases as
weld current increases.
Combined output of all receptacles
limited to 8 kVA/kW rating of the
generator.
GFCI Receptacle Option
1
120 V 20 A AC GFCI Recep-
tacles GFCI-2 and GFCI-3
GFCI2 and GFCI3 supply 60 Hz
single-phase power at weld/power
speed. Maximum output from
GFCI-2 or GFCI-3 is 2.4 kVA/kW.
Circuit breaker protection is the
same as standard receptacles.
If a ground fault is detected, the
GFCI Reset button pops out and
the circuit opens to disconnect the
faulty equipment. Check for
damaged tools, cords, plugs, etc.
connected to the receptacle. Press
button to reset receptacle and
resume operation.
.
At least once a month, run
engine at weld/power speed
and press Test button to verify
GFCI is working properly.
1
Ref. 206 422