6.1.2. Simple Timer

■ You can set the simple timer in any of three ways.

• Start time only:

The air conditioner starts when the set time has elapsed.

• Stop time only:

The air conditioner stops when the set time has elapsed.

• Start & stop times:

The air conditioner starts and stops at the respective elapsed times.

■ The simple timer (start and stop) can be set only once within a 72-hour

period.
The time setting is made in hour increments.

Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same time.
*2. The simple timer will not operate when any of the following conditions is in

effect.
The timer is off; the system is in malfunction state; a test run is in progress;
the remote controller is undergoing self-check or remote controller check;
the user is in the process of selecting a function; the user is in the process
of setting the timer; the system is under central control. (Under these con-
ditions, On/Off operation is prohibited.)

ON

Hr

AFTER

SIMPLE

PAR-21MAA

ON/OFF

FILTER

CHECK

OPERATION

CLEAR

TEST

TEMP.

MENU

BACK

DAY

MONITOR/SET

CLOCK

ON/OFF

2

q

9

0

4

1

w

ON

Hr

AFTER

SIMPLE

¢

¡

£

Timer Setting

Action (On or Off)

* “— —” is displayed if there is no

setting.

1. Be sure that you are at a standard control screen, and that the simple

timer indicator is visible in the display (at ¡).
When something other than the Simple Timer is displayed, set it to
SIMPLE TIMER using the function selection of remote controller (see
8.[4]–3 (3)) timer function setting.

2. Press the Timer Menu button w, so that the “Set Up” appears on the

screen (at ™). (Note that each press of the button toggles the display
between “Set Up” and “Monitor”.)

3. Press the ON/OFF button 1 to display the current ON or OFF simple

timer setting. Press the button once to display the time remaining to ON,
and then again to display the time remaining to OFF. (The ON/OFF
indication appears at £).
• “ON” timer:

The air conditioner will start operation when the specified number of
hours has elapsed.

• “OFF” timer:

The air conditioner will stop operation when the specified number of
hours has elapsed.

4. With “ON” or “OFF” showing at £: Press the appropriate Set Time button

q as necessary to set the hours to ON (if “ON” is displayed) or the hours
to OFF (if “OFF” is displayed) at ¢.
• Available Range: 1 to 72 hours

5. To set both the ON and OFF times, repeat Steps 3 and 4.

* Note that ON and OFF times cannot be set to the same value.

6. To clear the current ON or OFF setting: Display the ON or OFF setting

(see step 3) and then press the Check (Clear) button 0 so that the time
setting clears to “—” at ¢. (If you want to use only an ON setting or only
an OFF setting, be sure that the setting you do not wish to use is shown
as “—”.)

Timer Settings

˚F

TIMER

SUN

ON

OFF

WEEKLY

¡

ª

˚F

˚F

TIME SUN

WEEKLY

10

˚F

˚F

TIME SUN

WEEKLY

10

6. Timer

7. Press the appropriate Set Temperature button 3 to set the desired

temperature (at ¶).
* Each press changes the setting, in the following sequence: No

display (no setting)

⇔ 75 ⇔ 77 ⇔ ... ⇔ 84 ⇔ 86 ⇔ 54 ⇔ ... ⇔ 73

⇔ No display.
(Available range: The range for the setting is 12 °C, 54 °F to 30 °C,
86 °F. The actual range over which the temperature can be con-
trolled, however, will vary according to the type of the connected
unit.)

8. After making the appropriate settings at Steps 5, 6 and 7, press the

Filter

button 4 to lock in the values.

To clear the currently set values for the selected operation, press and
quickly release the Check (Clear) button 0 once.
* The displayed time setting will change to “—:—”, and the On/Off

and temperature settings will all disappear.
(To clear all weekly timer settings at once, hold down the Check
(Clear) button 0 for two seconds or more. The display will begin
flashing, indicating that all settings have been cleared.)

Note:
Your new entries will be cancelled if you press the Mode (Return) button
2

2

2

2

2 before pressing the Filter

button 4

4

4

4

4.

If you have set two or more different operations for exactly the same
time, only the operation with the highest Operation No. will be carried
out.

9. Repeat Steps 3 to 8 as necessary to fill as many of the available cells

as you wish.

10.Press the mode (Return) button 2 to return to the standard control

screen and complete the setting procedure.

11.To activate the timer, press the Timer On/Off button 9, so that the

“Timer Off” indication disappears from the screen. Be sure that the
“Timer Off” indication is no longer displayed.
* If there are no timer settings, the “Timer Off” indication will flash on

the screen.

1. Be sure that the weekly timer indicator is visible on the screen (at ¡).
2. Press the Timer Menu button w so that “Monitor” is indicated on the

screen (at •).

3. Press the Timer On/Off (Set Day) button 9 as necessary to select

the day you wish to view.

4. Press the

or

Operation button (7 or 8) as necessary to change

the timer operation shown on the display (at ª).
* Each press will advance to the next timer operation, in order of

time setting.

5. To close the monitor and return to the standard control screen, press

the Mode (Return) button 2.


Press the Timer On/Off button 9 so that “Timer Off” appears at ¤.


Press the Timer On/Off button 9 so that the “Timer Off” indication (at ¤)
goes dark.

10