Timer, Auto off timer – MITSUBISHI ELECTRIC PKA-AGAL User Manual
Page 10
10
7. After completing steps 3 to 6 above, press the Filter
button 4 to lock
in the value.
Note:
Your new settings will be cancelled if you press the Mode (Return) button 2
2
2
2
2
before pressing the Filter
button 4
4
4
4
4.
8. Press the Mode (Return) button 2 to return to the standard control
screen.
9. Press the Timer On/Off button 9 to start the timer countdown. When the
timer is running, the timer value is visible on the display. Be sure that the
timer value is visible and appropriate.
TIMER
ON
OFF
Hr
AFTER
SIMPLE
¡
§
∞
1. Be sure that the simple timer indicator is visible on the screen (at ¡).
2. Press the Timer Menu button w, so that the “Monitor” appears on the
screen (at ∞).
• If the ON or OFF simple timer is running, the current timer value will
appear at §.
• If ON and OFF values have both been set, the two values appear
alternately.
3. Press the Mode (Return) button 2 to close the monitor display and return
to the standard control screen.
pears on the screen (at ¶).
Timer Setting
˚F
˚F
SIMPLE
¶
˚F
˚F
ON
Hr
AFTER
SIMPLE
¶
at ¶.
Examples
If ON and OFF times have both been set at the simple timer, operation and
display are as indicated below.
Example 1:
Start the timer, with ON time set sooner than OFF time
ON Setting: 3 hours
OFF Setting: 7 hours
ON
Hr
AFTER
SIMPLE
˚F
˚F
OFF
Hr
AFTER
SIMPLE
SIMPLE
˚F
˚F
OFF
Hr
AFTER
SIMPLE
ON
Hr
AFTER
SIMPLE
▲
▲
▲
At 3 hours after timer start
Display changes to show the timer’s OFF set-
ting (hours remaining to OFF).
The time displayed is OFF setting (7 hours) –
ON setting (3 hours) = 4 hours.
At Timer Start
Display shows the timer’s ON setting (hours
remaining to ON).
At 7 hours after timer start
The air conditioner goes off, and will remain off
until someone restarts it.
˚F
˚F
SIMPLE
▲
At 2 hours after timer start
Display changes to show the timer’s ON setting
(hours remaining to ON).
The time displayed is ON setting (5 hours) –
OFF setting (2 hours) = 3 hours.
At Timer Start
Display shows the timer’s OFF setting (hours
remaining to OFF).
At 5 hours after timer start
The air conditioner comes on, and will continue
to run until someone turns it off.
6.1.3. Auto Off Timer
■ This timer begins countdown when the air conditioner starts, and shuts
the air conditioner off when the set time has elapsed.
■ Available settings run from 30 minutes to 4 hours, in 30-minute intervals.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same time.
*2. The Auto Off timer will not operate when any of the following conditions is
in effect.
The timer is off; the system is in malfunction state; a test run is in progress;
the remote controller is undergoing self-check or remote controller check;
the user is in the process of selecting a function; the user is in the process
of setting the timer; the system is under central control. (Under these con-
ditions, On/Off operation is prohibited.)
AFTER
OFF
AUTO OFF
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK
DAY
MONITOR/SET
CLOCK
ON/OFF
2
q
9
4
w
AFTER
OFF
AUTO OFF
£
¡
™
Timer Setting
1. Be sure that you are at a standard control screen, and that the Auto Off
timer indicator is visible in the display (at ¡).
When something other than the Auto Off Timer is displayed, set it to
AUTO OFF TIMER using the function selection of remote controller (see
8.[4]–3 (3)) timer function setting.
2. Hold down the Timer Menu button w for 3 seconds, so that the “Set Up”
appears on the screen (at ™).
(Note that each press of the button toggles the display between “Set Up”
and “Monitor”.)
3. Press the appropriate Set Time button q as necessary to set the OFF
time (at £).
4. Press the Filter
button 4 to lock in the setting.
Note:
Your entry will be cancelled if you press the Mode (Return) button 2
2
2
2
2 before
pressing the Filter
button 4
4
4
4
4.
5. Press the Mode (Return) button 2 to complete the setting procedure and
return to the standard control screen.
6. If the air conditioner is already running, the timer starts countdown
immediately. Be sure to check that the timer setting appears cor-
rectly on the display.
Example 2:
Start the timer, with OFF time is sooner than ON time
ON Setting: 5 hours
OFF Setting: 2 hours
6. Timer
BG79U794H02_en
05.12.22, 2:02 PM
10