beautypg.com

Unit:mm – MITSUBISHI ELECTRIC SRK50Z J-S User Manual

Page 25

background image

-

24

-

'10 • SR-T-091D

(b) Wired remote controller (option parts)

PJZ000Z274

TEMP

ON/OFF

48

غ

120

L C D

Wall surface

Wiring

Electrical box

Not included䋩

19

Wiring specifications

Exposed mounting

23

46

11.5

11

Remote

control

outline

120

45

83.5

42

120

Remote control installation dimensions

Wiring oulet

Installation hole

12×7 Slot hole

9.5×5 Slot hole 䋨4places䋩

1䋩 Installation screw for remote control

M4 Screw (2 pieces)

44

(1) If the prolongation is over 100m, change to the size below.

But, wiring in the remote controller case should be under 0.5mm

2

. Change the wire size outside of

the case according to wire connecting. Waterproof treatment is necessary at the wire connecting

section. Be careful about contact failure.

Length

Wiring thickness

100 to 200m

0.5mm

2

×2 cores

0.75mm

2

×2 cores

1.25mm

2

×2 cores

2.0mm

2

×2 cores

Under 300m
Under 400m
Under 600m

Upper part

Lower part

Lower case

Sheath

Upper cace

Board

Wiring

Upper

Lower

X

Y

Sheath

Upper cace

Board

Wiring

Upper

Lower

Y

X

Tighten the screws after

cutting off the thin part of

screw mounting part.

Embedded mounting

The peeling-off length of sheath

The peeling-off length

of sheath

In case of pulling out from

upper left

In case of pulling out

from upper left

In case of pulling out

from upper left

X wiring : 170mm
Y wiring : 190mm

Pulling out from center

X wiring : 215mm
Y wiring : 195mm

Pulling out from upper left

In case of pulling out from center

In case of pulling out

from center

In case of pulling out

from center

Wiring outlet

Cut off the upper thin part of remote control lower case with a nipper or knife,

and grind burrs with a file etc.

0.3mm

2

×2 cores.

X, Y Terminal block
Attach M3 screw

with washer

Unit:mm