beautypg.com

MITSUBISHI ELECTRIC SRK50Z J-S User Manual

Page 10

background image

-

-

'10 • SR-T-091D

A

RWB000Z053

Model

Item

SRF35ZJX-S

Indoor unit

SRF35ZJX-S

Outdoor unit

SRC35ZJX-S

Cooling capacity (1)

W

3500 (900 (Min.)~4100 (Max.))

Heating capacity (1)

W

4500 (900 (Min.)~5100 (Max.))

Power supply

1 Phase, 220~240 V, 50Hz

Operation
data (1)

Power
consumption

Cooling

kW

0.890 (0.19~1.26)

Heating

1.124 (0.23~1.43)

Running
current

Cooling

A

4.1 / 3.9 / 3.7 (220/ 230/ 240 V)

Heating

5.2 / 4.9 / 4.7 (220/ 230/ 240 V)

Inrush current

5.2 / 4.9 / 4.7 (220/ 230/ 240 V)

COP

Cooling

3.93

Heating

4.00

Noise
level

Cooling

Sound level

dB(A)

Hi : 41 Me : 34 Lo : 28

50

Power level

dB

52

63

Heating

Sound level

dB(A)

Hi : 41 Me : 36 Lo : 31

50

Power level

dB

52

62

Exterior dimensions (Height x Width x Depth)

mm

600 x 860 x 238

595 x 780 x 290

Exterior appearance
( Munsell color )

Fine snow

( 8.0Y 9.3/0.1 ) near equivalent

Stucco white

( 4.2Y 7.5/1.1 ) near equivalent

Net weight

kg

19

38

Refrigerant
equipment

Compressor type & Q'ty

RM-B5077MDE1 (Rotary type) x 1

Motor (Starting method)

kW

0.90 (Line starting)

Refrigerant oil

0.35 (DIAMOND FREEZE MA68)

Refrigerant (3)

kg

R410A 1.2 (Pre-Charged up to the piping length of 15m)

Heat exchanger

Louver fins & inner grooved tubing

M fins & inner grooved tubing

Refrigerant control

Capillary tubes + Electronic expansion valve

Deice control

Microcomputer control

Air handling
equipment

Fan type & Q'ty

Turbo fan x 1

Propeller fan x 1

Motor

W

40

24

Air flow

Cooling

CMM

Hi : 9.2 Me : 7.8 Lo : 6.4

32.5

Heating

Hi : 10.7 Me : 8.3 Lo : 7.4

29.5

Fresh air intake

Impossible

Air filter, Quality / Quantity

Polypropylene net (washable) x 1

Shock & vibration absorber

Cushion rubber (for compressor)

Electric heater

Operation
control

Operation switch

Wireless-Remote control

Room temperature control

Microcomputer thermostat

Operation Display

RUN : Green, TIMER : Yellow, HI POWER : Green,

AIR OUTLET SELECTION : Green, ECONO : Green

Safety devices

Compressor overheat protection, Overcurrent protection,

Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection

Installation
data

Refrigerant piping size (O.D)

mm

Liquid line :

φ6.35 (1/4") Gas line :φ9.52 (3/8")

Connecting method

Flare connecting

Attached length of piping

m

Insulation for piping

Necessary (Both sides), independent

Refrigerant line (one way) length

m

Max. 15

Vertical height difference between
outdoor unit and indoor unit

Max. 10 (Outdoor unit is higher)

Max.10 (Outdoor unit is lower)

Drain hose

Connectable (VP16)

Power cable

Recommended breaker size

A

16

Connection wiring

Size x Core number

1.5mm

2

x 4 cores (Including earth cable)

Connecting method

Terminal block (Screw fixing type)

Accessories (included)

Mounting kit, Clean filter (Natural enzyme filter x 1, Photocatalytic washable deodorizing filter x 1)

Optional parts

Interface kit (SC-BIKN-E)

Note (1) The data are measured at the following conditions.

Item

Operation

Indoor air temperature

Outdoor air temperature

Standards

DB

WB

DB

WB

Cooling

27˚C

19˚C

35˚C

24˚C

ISO-T1, JIS C 9612

Heating

20˚C

7˚C

6˚C

(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)

The pipe length is 7.5m.

Adapted to