8.

8. Move the microphone to the second listening

position, select “

START

” with the

3

/

4

cursor

buttons and press the

ENTER

button to

measure the second point. At this point, you
can cancel second point measurement and
calculate measurement results by selecting

CALCULATE

” and pressing the

ENTER

button.

A U T O S E T U P

S P E A K E R S C H E C K : O K

2 N D M I C P O S I T I O N ! !
S T A R T

C A L C U L A T E

E X I T

9.

Repeat steps 7 and 8 until measuring 6

points between the main listening position and
surrounding positions.

When all measurements end, the following

OSD appears on the display.

A U T O S E T U P

S P E A K E R S C H E C K : O K

C A L C U L A T E

E X I T

Select

CALCULATE

” with the

3

/

4

cursor

buttons and press the

ENTER

button to calculate

measurement results. During calculations, the
following OSD appears on the display.

A U T O S E T U P

_ _ _ _ _ _ _ _ _ _ _ _ _ _

N O W C A L C U L A T E ! !

E X I T

Note:

• Less than 6 positions can be measured, but it is

recommended to measure in all 6 positions in order
to obtain the best results.

• The time needed to complete calculations depends

on the number of connected speakers and measured
listening positions. The more speakers and listening
positions, the more time is needed.

[Example]

Confi rmation screen for speaker size and

crossover frequency

S P E A K E R S I Z E

F R O N T L : A U T O
C E N T E R : A U T O
F R O N T R : A U T O
S U R R . R : A U T O
S U R R . B R : A U T O
S U R R . B L : A U T O
S U R R . L : A U T O
S U B W : A U T O

R E T U R N

N E X T

C R O S S O V E R F R E Q

F R O N T : A U T O
C E N T E R : A U T O
S U R R : A U T O
S U R R . B : A U T O

R E T U R N

* AUTO is displayed to indicate that the speaker size

and crossover frequency results were automatically
measured.

11.

Storing Measurement Results in Memory

Once finished confirming the measurement

results, select “

RETURN

” with the

3

/

4

cursor

buttons and press the

ENTER

button to display

the CHECK RESULT screen.

C H A N N E L L E V E L

F R O N T L : 0 . 0 d B
C E N T E R : - 6 . 5 d B
F R O N T R : - 1 . 5 d B
S U R R . R : + 1 . 0 d B
S U R R . B R : + 9 . 5 d B
S U R R . B L : + 1 2 . 0 d B
S U R R . L : - 2 . 5 d B
S U B W : - 1 2 . 5 d B

R E T U R N

N E X T

C H E C K R E S U L T

S P E A K E R C O N F I G
S P E A K E R S I Z E
D I S T A N C E
C H A N N E L L E V E L
C R O S S O V E R F R E Q

S T O R E

E X I T

Place the cursor on “

STORE

” and press

the

ENTER

button to store all parameters

including the equalizer parameters in memory.
If not wanting to store the calculation results in
memory, place the cursor on “

EXIT

” and press

the

ENTER

button.

10.

Checking Measurement Results

When calculations for the measurement results

end, a screen appears for confirming the
calculation results.

C H E C K R E S U L T

S P E A K E R C O N F I G

S P E A K E R S I Z E
D I S T A N C E
C H A N N E L L E V E L
C R O S S O V E R F R E Q

S T O R E

E X I T

Select items to check with the

3

/

4

cursor

buttons and press the

ENTER

button to enter

them.

Note:

To check equalizer (MultEQ) parameters, see page
42.

[Example]

Confi rmation screen for speaker detection

S P E A K E R C O N F I G
C H E C K ! ! S P E A K E R
F R O N T : Y E S
C E N T E R : N O N
F R O N T R : Y E S
S U R R . R : Y E S
S U R R . B R : N O N
S U R R . B L : N O N
S U R R . L : Y E S
S U B W : Y E S

R E T U R N

N E X T

[Example]

Confi rmation screen for the distance from

speakers to the listening position

D I S T A N C E
U N I T :

m

F R O N T L : 3 . 0 5 m
C E N T E R : 3 . 0 5 m
F R O N T R : 3 . 0 5 m
S U R R . R : 3 . 0 5 m
S U R R . B R : 3 . 0 5 m
S U R R . B L : 3 . 0 5 m
S U R R . L : 3 . 0 5 m
S U B W : 3 . 0 5 m

R E T U R N N E X T

* The units can be changed by moving the cursor to

[ft] of UNIT and pressing

1

/

2

the cursor buttons.

Each time a

1

/

2

cursor button is pressed, the units

alternate between [ft] (feet) and [m] (meters).

Note:

Pressing “EXIT” prior to pressing “STORE” erases all
measurement results and calculation results, therefore
operate the remote control unit with care.

When storing operations end, the following OSD
appears on the display.

2 . S P K R S E T U P

A U T O S E T U P

M A N U A L S E T U P

R E T U R N

E X I T

Note:

• Do not turn the power to the SR6001 off while

storing parameters in memory. This may erase all
data in the SR6001’s memory and may damage the
receiver.