beautypg.com

Product specifications – Monessen Hearth VFCS20DNV User Manual

Page 8

background image

8

58D6002

PRODUCT SPECIFICATIONS

NATURAL GAS

NOTE: An external regulator is required to reduce supply pressure to a maximum of 10

1

/

2

" w.c. on Natural Gas

systems operating at higher pressure.

MILLIVOLT PRESSURE
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator:

3.5" w.c.

Gas Inlet Pressure:

Max. 10 1/2" w. c.

Min. 5" w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches.

Millivolt control has four (4) positions:

OFF

-

All gas to the burner is shut off at the valve.

IGN

-

Valve position to light/maintain a standing pilot.

ON

-

Valve position to turn burners ON/OFF with remote switch.

LOW/HI -

Variable position to control flame height (heat output). Both front and rear burners are in
operation to provide realistic glow and yellow flame.

PILOT/ODS

The gas log heater is fitted with a specially designed safety pilot (ODS assembly) light which senses the amount
of oxygen available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satis-
factory level. The pilot can only be relit when adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a millivolt thermopile generator to provide power for remote activation.

PROPANE / LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.

MILLIVOLT PRESSURE
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure:

Maximum 13" w.c.

Minimum 11" w.c.

Model Number

Type

Gas Rate

Max. BTU/Hr

Min. BTU/Hr

CSVF20SNV/VFCS20DNV (G-EBL-ES-EMB)
CSVF30SNV/VFCS30DNV (G-EBL-ES-EMB)

Millivolt
Millivolt

10,000
32,000

6,000

20,000

Model Number

Type

Gas Rate

Max. BTU/Hr

Min. BTU/Hr

CSVF20SPV/VFCS20DPV (G-EBL-ES-EMB)
CSVF30SPV/VFCS30DPV (G-EBL-ES-EMB)

Millivolt
Millivolt

10,000
32,000

6,000

20,000