1 v.42 error correction modes, 2 modem-initiated flow control, 3 xon/xoff pass-through – Multi-Tech Systems MT2834MR6 User Manual
Page 74: 4 hewlett packard enq/ack pacing, 5 non-error correction mode flow control, 6 pacing (computer-initiated flow control), 7 data compression, 10 compression, error correction, flow control, And pacing commands

74
Chapter 5 - Error Correction, Data Compression, and Speed Conversion
5.10 Compression, Error Correction, Flow Control,
and Pacing Commands
The MT2834MR6 has several commands that control error correction, data compression, and flow control:
5.10.1 V.42 Error Correction Modes
&E0
Non-auto correction mode (no error correction).
&E1
Autoreliable mode (factory default).
&E2
Reliable mode.
5.10.2 Modem-Initiated Flow Control
&E3
Disable flow control.
&E4
CTS/RTS hardware flow control (factory default).
&E5
XON/XOFF software flow control.
5.10.3 XON/XOFF Pass-Through
&E6
Respond to and discard XON/XOFF characters when &E5 is selected (factory
default).
&E7
Respond to and pass through XON/XOFF characters when &E5 is selected.
5.10.4 Hewlett Packard ENQ/ACK Pacing
&E8
Ignore ENQ/ACK pacing characters (factory default).
&E9
Respond to ENQ/ACK pacing characters.
5.10.5 Non-Error Correction Mode Flow Control
&E10
Non-error correction mode flow control off (factory default).
&E11
Non-error correction mode flow control on.
5.10.6 Pacing (Computer-Initiated Flow Control)
&E12
Pacing off.
&E13
Pacing on (factory default).
5.10.7 Data Compression
&E14
Data Compression disabled.
&E15
Data Compression enabled.*
* The factory default setting for data compression is enabled, but the modem will not compress data unless
&E1
(autoreliable mode) or
&E2
(reliable mode) is also selected.