DCa70USI2 60 hz generaTor • operaTIon anD parTS manUal — rev. #0 (06/28/11) — page 49

trOuBleshOOting (diagnOstic laMp)

The engine controller of this generator diagnoses problems

that arise from the engine control system and the engine

itself. Press the diagnostic button (Figure 66) on the

diagnostic panel to determine if an engine malfunction has

occurred.

Figure 66. Diagnostic Panel

meThoD oF operaTIon

1. Normally, the diagnostic lamp will be

dimly lit when

the

mpeC Control Switch is placed in the manUal

position.

2. If engine trouble occurs, the diagnostic lamp will be

brightly lit as long as the control switch is left in the

manual position.

3. The diagnostic lamp will indicate that an engine

malfunction has occurred.

NOTICE

For a complete understanding of error codes and

troubleshooting procedures, refer to the enclosed

engine instruction manual.

NOTICE

If the engine is cranked while the diagnostic switch is in

the “

on” position, the engine will not be stopped even if

the starter switch is turned to the “

oFF” position. In such

case, turn the diagnostic switch to the “

oFF” position.