INSTALLATION, RELOCATION AND INSPECTION

Installation place

Avoid installing the air conditioner in the following places.

Where flammable gas could leak.

CAUTION:

Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause
an explosion.

Where there is much machine oil.

Salty places such as the seaside.

Where sulfide gas is generated such as a hot spring.

Where oil is splashed or where the area is filled with
oily smoke.

Where there is high-frequency or wireless equipment.

CAUTION:

• Ground the unit.

Do not connect the ground to a gas pipe, water pipe, lightning rod or the ground of a telephone. If the grounding is
incorrect, it may cause an electric shock.

• If the air conditioner is installed in a high humidity area or near a water source, a Ground Fault Interrupt (GFI) circuit

breaker should be installed to protect against an electric shock.

Inspection and maintenance

When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.

Depending on the condition, an odor may be generated or dehumidified water may not drain out smoothly due to dirt,
dust, etc.

It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.
Consult your dealer.

Operating sound considerations

Do not put an object around the air outlet of the outdoor unit. This may lower the capacity or increase the volume of the
operating sound.

If an abnormal sound is heard during operation, consult your dealer.

Relocation

When the air conditioner is to be removed or re-installed because of rebuilding, moving, etc., special techniques and work
are required.

WARNING:

Repairs or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, an electric shock, or an injury from the unit falling, water leaking, etc.
Consult your dealer.

Disposal

To dispose of this product, consult your dealer.

If you have any questions, consult your dealer.

WARNING:

If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be
generated.

Electrical work

Provide an exclusive circuit for the power supply of the air conditioner.

Be sure to observe the breaker capacity.

Use the correct power (voltage and frequency) indicated on the unit to operate the air conditioner and use only fuses or
breakers with specified capacity. Do not use pieces of wire instead of fuses.

WARNING:

• The customer should not install this unit.

If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking,
etc.

• Do not use intermediate connection of the power supply cord or the extension cord and do not connect many

devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.

• The unit should be installed by licensed contractor according to local code requirements.

To prevent the effects
of a fluorescent lamp,
keep as far apart as
possible.

Wall, etc.

Inverter-type
fluorescent lamp

Keep a space
to prevent the
picture
distortion or
the noise.

3 ft.

or more

Radio

4 in. or
more

Well-
ventilated
dry place

20 in. or
more

TV

Cordless
phone or
Portable
phone

10 ft.

or more

3 ft.

or more

* The required space depends on the type of outdoor unit.

The installation location of the outdoor unit should be at least
10 ft. away from the antennas for TV sets, radios, etc. In areas
where the reception is weak, provide greater space between
the outdoor unit and the antenna of the affected device if op-
eration of the air conditioner interferes with radio or TV recep-
tion.