Troubleshooting, Glass replacement, Blower – Monessen Hearth 6000DV User Manual
Page 45: Caution, Warning

42D0200
45
120 VAC
Blower
120 VAC
Speed Control
Green
Green
Attach Blower to T-Stat
Black
Black
Black
White
Blower Plug
Junction Box
ON/OFF Wall Switch or
Optional Variable Speed Switch
120 VAC
60Hz
Factory Supplied
Not Supplied
TROUBLESHOOTING
GENERAL TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE
ACTION
1. Glass Soots
A. Flame impingement on logs
A. Install log set per the instructions
Inspect the injector and air intake area. Make sure this area does
not have any blockage from debris and clean.
Check gas supply.
2. Flame burn
blue and lifts
off burner
(ghosting)
A. Insufficient oxygen being supplied
A. Ensure that the vent cap is installed properly and free of debris.
Ensure that the vent system joints are tight and have no leaks.
Ensure that no debris has been blocking the inner air intake at the
bottom back of the combustion chamber. Ensure that the glass is
properly secure and latch.
GLASS REPLACEMENT
AND
BLOWER
• Never operate fireplace if glass is broken.
• Replace any glass that is chipped, cracked, or broken. Replacement glass assemblies MUST be supplied by fireplace
manufacturer — No substitute materials may be use.
Always use gloves when handling
broken glass.
CAUTION
Make sure the glass panel edges
do not touch any metal parts during
thermal expansion.