VERTICAL THROUGH-THE-ROOF APPLICATIONS

This Gas Fireplace has been approved for,
• Vertical installations up to 40' (12m) in height. Up to a 10' (3m) horizontal vent run can be installed within the vent system

using a maximum of two 90° elbows. See Figure 33.

Figure 33 - Support Straps for Horizontal Runs

VENT INSTALLATION

Figure 34 - Maximum elbow Usage

• Up to two 45° elbows may be used within the

horizontal run. For each 45° elbow used on
the horizontal plane, the maximum horizontal
length must be reduced by 18" (450mm).

Example: Maximum horizontal length

No elbows = 10’ (3m)

1x45° elbows = 8.5’ (2.6m)

2x45° elbows = 7’ (2.1m)

• A minimum of an 8' (2.5m) vertical rise is

required.

• Two sets of 45°elbows offsets may be used within

the vertical sections. From 0 to a maximum of 8'

(2.5 m) of vent pipe can be used between elbows.

See Figure 34.

• The maximum angular variation allowed in the

system is 270°. See Figure 34.

• The minimum height of the vent above the high-

est point of penetration through the roof is 2'

(610mm).

40' Maximum Height

8' Minimum Height

40' Maximum Height

8' Minimum Height

10'

Maximum

10'

Maximum

1

2

3

4

1

2

3

4

Support Straps

Every 3'

Support Straps

Every 3'

Example:

Elbow 1 = 90°

Elbow 2 = 45°

Elbow 3 = 45°

Elbow 4 = 90°

Total Angular Variation = 270°