Fan Kit

FK26 Fan

The FK26 fan helps distribute heated air from within
the firebox out into the room. The fan is controlled by a
snapstat that turns power on and off as the firebox
temperature rises above and falls below a preset
temperature. A rheostat provides for variable fan
speeds.

Specifications

115 Volt / 60Hz / .75 Amps

Maintenance

The fan itself does not require regular maintenance,
however, periodic cleaning of the fan and the
surrounding area is required.

Installation

1. Place fan assembly at the back of the unit between

hearth supports. Attach using velcro strips provided.
(Fig. 32)

2. Install thermal sensor (snapstat) on bottom of

firebox by sliding between bracket and firebox.

3. Place electronic fan speed control box (rheostat) to

side bracket. Fasten fan speed control box with #10
- 24 hex nuts.

4. If the EB-1 receptacle box (Pt. #ZA1200) was

correctly connected when the unit was installed, the
fan lead can be directly plugged into the EB-1 plug
socket.

The fireplace, when installed must be
electrically connected and grounded in
accordance with local codes, with the
current CSA C22.1 Canadian Electrical
Code or for US installations, follow local
codes and the National Electrical Code,
ANSI/NFPA No. 70.

Any electrical rewiring of this fan must
be completed by a qualified electrician.

Turn off all power before hook up.

Fan

Heat Sensor
(Snapstat)

Electrical
Box

Fan Speed Switch
(Rheostat)

FP1323

Fig. 32 FK26 fan placement.

Trim Kits

A cast face trim kit and a cast louvre kit are available to
enhance the look of your EWF36A fireplace.
Installation instructions are included with the kit.

Model

Description

EWF36ACFTK

Cast Face Trim Kit

EWF36ACLK

Cast Louvre Kit

Screen Kit

An optional spark screen, EWF36S, is available to
allow the fireplace to be operated with the doors fully
open.

NOTE: When operated with the doors open and the
screen in place, the damper MUST be in the open
position.